From the paper's conclusion
  • Despite sharing the same pulsed Thulium:yttrium-aluminium-garnet laser medium, the two platforms exhibited distinct laser-stone interaction profiles. Further clinical evaluation is warranted to determine the relevance of these differences.

Abstract

OBJECTIVE: Our objective was to compare bubble appearance, retropulsion kinetics, and lithotripsy efficiency between two pulsed Thulium:yttrium-aluminium-garnet laser platforms with distinct engineering characteristics, including pumping configuration and peak-power capability. MATERIALS AND METHODS: We compared the RevoLix HTL (LISA Laser Products GmbH) and the Thulio (Dornier MedTech GmbH) across six settings (0.2-1.0 J, 10-50 Hz, short/long pulse). Standardized 5 × 5 × 5 mm artificial stones on a V-shaped rail and calcium oxalate dihydrate dust from one clinical case were evaluated. Imaging was used to qualitatively assess bubbles, and Kinovea and a custom Python pipeline quantified the retropulsion and dust particle area. An equal-weight composite score summarized stone weight loss and retropulsion. RESULTS: Qualitative imaging demonstrated that the RevoLix HTL produced well-defined bubble outlines, whereas the Thulio generated less defined outlines. The Thulio showed pulsatile retropulsion, whereas the RevoLix HTL exhibited smoother displacement and lower mean retropulsion at all six settings (e.g., 1.0 J/10 Hz long pulse: mean ± standard deviation [SD] 3.1 ± 0.6 vs. 15.3 ± 2.1 mm; mean difference -12.1 mm [95% confidence interval -15.3 to -8.9]). In fixed-stone tests, the Thulio achieved greater stone weight loss at 0.4 J/25 Hz long pulse (mean ± SD 17.5 ± 5.0 vs. 35.0 ± 5.8 mg; mean difference -17.5 mg [95% confidence interval -26.9 to -8.1]). At equal weighting, RevoLix HTL had a higher composite score at five of six settings, although the ranking was weighting dependent. Exploratory particle analysis showed smaller particle areas with RevoLix HTL at all three settings. CONCLUSION: Despite sharing the same pulsed Thulium:yttrium-aluminium-garnet laser medium, the two platforms exhibited distinct laser-stone interaction profiles. Further clinical evaluation is warranted to determine the relevance of these differences.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Platform differences: Retropulsion, fragmentation, and dust in pulsed thulium:YAG lithotripsy — Science Skim