Restoring Arterial Pulsatility via Speed Modulation in Ventricular Assist Devices: A Structured Narrative Review and Mechanistic Windkessel-Based Analysis.
Peng Fang, Zhongqi An, Haiquan Feng, Rundong Wang, Yating Zhang, Jinbo Wang
College of Mechanical Engineering, Inner Mongolia University of Technology, Hohhot, China.
Key points
From the paper's conclusion- Speed modulation can enhance arterial pulsatility under animal and computational conditions, but its clinical effectiveness remains limited. This discrepancy may reflect constraints on modulation amplitude and duration imposed by hemocompatibility, ventricular safety, and device reliability. Future research should integrate multiscale hemodynamic and hemocompatibility assessments, long-term animal and clinical validation, and advanced device designs and control strategies.
Abstract
BACKGROUND: Continuous-flow ventricular assist devices (CF-VADs) attenuate arterial pulsatility, potentially predisposing patients to complications such as endothelial dysfunction and gastrointestinal bleeding. Speed modulation has been proposed to reconstruct arterial pulsatility, but its effectiveness and underlying mechanisms remain incompletely understood. METHODS: A structured narrative review was conducted using studies identified from PubMed, Scopus, and Web of Science through June 2026. Evidence from animal experiments, mock circulatory loop studies, lumped-parameter models, and clinical investigations was synthesized. A Windkessel-based framework was used to interpret the effects of modulation parameters on arterial pulsatility. RESULTS: Animal and computational studies generally demonstrate that speed modulation can enhance arterial pulsatility, with the enhancement depending on factors such as modulation amplitude, waveform, frequency (i.e., the duration of high- and low-speed phases) and phase relationship. Windkessel-based analysis further indicates that pulsatility enhancement is governed by differences in flow-time integrals between modulation phases, providing a mechanistic explanation for the observed effects of modulation parameters. However, clinically implemented speed modulation algorithms have not consistently produced significant improvements in arterial pulsatility or vascular function. CONCLUSIONS: Speed modulation can enhance arterial pulsatility under animal and computational conditions, but its clinical effectiveness remains limited. This discrepancy may reflect constraints on modulation amplitude and duration imposed by hemocompatibility, ventricular safety, and device reliability. Future research should integrate multiscale hemodynamic and hemocompatibility assessments, long-term animal and clinical validation, and advanced device designs and control strategies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ventriculo-Arterial Coupling and Speed Modulations in Rotodynamic Blood Pumps.American journal of physiology. Heart and circulatory physiology · 2026
- Pulsatility as a Potential Regulator of Cardiovascular Biology: Molecular, Cellular, and Hemodynamic Remodeling During Continuous-Flow Left Ventricular Assist Device Support and Following Heart Transplantation.International journal of molecular sciences · 2026
- Impact of dynamic pump speed adjustment versus constant speed in left ventricle assist device patients on exercise performance: A systematic review and meta-analysis.Perfusion · 2026
- Computational Fluid Dynamics Analysis of Percutaneous left ventricular assist device Support Modes on Ventricular Hemodynamics and Hemocompatibility.Medical engineering & physics · 2026
- Dynamic Arterial Elastance: Physiologic Basis, Current Clinical Evidence, and Future Directions.Anesthesiology · 2026
- Impact of Pulsatile Flow on Pulmonary Transvascular Fluid Flux During Veno-Pulmonary Arterial ECMO: A Pilot Ovine Study.Shock (Augusta, Ga.) · 2026