False-Positive Hepatitis C Virus Serology Following HeartMate 3 Left Ventricular Assist Device Implantation.
Chae Rin Im, Olly Allen, A Ruth M Kappeler, Sumita Pai, Jo Pocock, Sai Bhagra, Marius Berman, Paul Lincoln,
Department of Microbiology, Royal Papworth Hospital, Cambridge, UK. · Transplant Unit, Royal Papworth Hospital, Cambridge, UK.
Key points
From the paper's conclusion- FPHC serology is a clinically important phenomenon in HeartMate 3 LVAD recipients. Clinicians and patients should be aware of this phenomenon to minimize unnecessary investigations and delays to transplant candidacy assessment. Standardized confirmatory testing protocols and multicenter studies are needed to clarify the underlying immune mechanisms and their impact on post-transplant outcomes.
Abstract
BACKGROUND: False-positive hepatitis C virus (HCV) (FPHC) serology has been reported with earlier-generation axial-flow left ventricular assist devices (LVADs), but its frequency with the magnetically levitated HeartMate 3 and its implications for heart transplant pathways remain unknown. This study describes FPHC serology in HeartMate 3 LVAD recipients and explores associated clinical and immunological features. METHODS: A retrospective, single-center study was conducted at a specialist cardiothoracic center. All adults implanted with a HeartMate 3 LVAD between March 2018 and July 2025 with complete HCV serology before and after implantation were included. Patients developing HCV antibody positivity with negative confirmatory testing were classified as having FPHC serology. Patient demographics, blood product transfusions, liver function tests, lactate dehydrogenase, and human leukocyte antigen (HLA) sensitization were compared between groups. RESULTS: Among 54 HeartMate 3 LVAD recipients, 10 (18.5%) developed FPHC serology after implantation. There were no significant differences between groups in age, sex, liver function tests, or lactate dehydrogenase. The number of fresh frozen plasma units transfused at implantation and the development of anti-HLA Class I antibodies were associated with FPHC serology (p = 0.039, p = 0.04, respectively). No significant associations were observed with red blood cell or platelet transfusions. CONCLUSION: FPHC serology is a clinically important phenomenon in HeartMate 3 LVAD recipients. Clinicians and patients should be aware of this phenomenon to minimize unnecessary investigations and delays to transplant candidacy assessment. Standardized confirmatory testing protocols and multicenter studies are needed to clarify the underlying immune mechanisms and their impact on post-transplant outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Reduced Adverse Events Without Survival Benefit With HeartMate 3 vs. HeartMate II in Japan.Circulation journal : official journal of the Japanese Circulation Society · 2026
- Intravascular hemolysis and clinical outcomes in continuous-flow LVAD patients: A single-center retrospective analysis.The International journal of artificial organs · 2026
- Assessment of the predictive value of right ventricular longitudinal strain and functional trends in right ventricular function of patients after LVAD implantation.The international journal of cardiovascular imaging · 2026
- Real-World Hemocompatibility Outcomes With Aspirin Omission in a Novel Fully Magnetically Levitated Left Ventricular Assist Device.ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2026
- SGLT2 inhibitors and outcomes in the chronic Post-LVAD phase: a multicenter real-world cohort study.Frontiers in pharmacology · 2026
- Predicting Survival Beyond 5 Years On Continuous-Flow LVAD: A Landmark Analysis From The STELLAR Registry.ESC heart failure · 2026