Automated Insulin Delivery in Pregnancies Complicated by Type 1 Diabetes: A Real World Observational Study of Available Systems
Stephanie L. Teasdale, Julian Pavey, Melissa Lee, Janelle C. Nisbet
Key points
From the paper's conclusion- Background Only one automated insulin delivery (AID) system is licensed in Australia for use in pregnancies complicated by Type 1 diabetes (T1D); however, some women using other AID systems have continued to use these ‘off‐label’ in pregnancy.
Abstract
Background Only one automated insulin delivery (AID) system is licensed in Australia for use in pregnancies complicated by Type 1 diabetes (T1D); however, some women using other AID systems have continued to use these ‘off‐label’ in pregnancy. Usage patterns from a single centre in Australia will be of interest to clinicians supporting women with T1D in pregnancy. Aims This is an observational study evaluating outcomes in women treated with different AID systems through a pregnancy cared for at a tertiary maternity centre. Materials and Methods All women using AID in one or more trimesters of pregnancy through a 3‐year study period are included in the reporting of glycaemic and insulin delivery measures in each trimester of pregnancy. All women using AID throughout the duration of a pregnancy within the study period are included in the reporting of birth outcomes. Results Four AID systems had been used during the study period, MiniMed with Smartguard, T:slim with Control IQ, YpsoMed with CamAPS and Omnipod with SmartAdjust. Small numbers of YpsoMed and Omnipod users precluded these from statistical analysis. Women using MiniMed and T:slim AID systems differed in terms of early HbA1c and smoking history with MiniMed users representing suboptimal pre‐pregnancy diabetes control. Use of continuous glucose monitoring (CGM) was additionally significantly lower for users of the MiniMed system. Median pregnancy‐specific time in range (pTIR) was above 62% for all systems by trimester 2 and above 64% for all systems by trimester 3 with no significant difference between MiniMed and T:slim systems. There was less pregnancy‐specific time below range (pTBR) and/or time well below range (pTWBR) for the MiniMed system in all trimesters compared with the T:slim system. Conclusions AID systems without the tight target considered necessary for pregnancy were still able to achieve good glycaemic outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Real-world use of automatic insulin delivery pumps in early pregnancy among women living with type 1 diabetes.Diabetic medicine : a journal of the British Diabetic Association · 2026
- Automated Insulin Delivery in Pregnancy With Type 1 Diabetes: An Integrative Review of Clinical Evidence, Socio-Technical Implementation and Equity.Journal of diabetes research · 2026
- Commercial Automated Insulin Delivery Systems in Type 1 Diabetes Pregnancy: Protocol for a Mixed-Methods Systematic Review and Meta-Analysis of Glycaemic, Perinatal, Psychosocial and Implementation Outcomes.Endocrinology, diabetes & metabolism · 2026
- Automated Insulin Delivery for Pregnancy With Type 1 Diabetes: A Call to Action.Diabetes care · 2026
- Management of Automated Insulin Delivery Systems in Pregnant Individuals With Type 1 Diabetes: Practical Tips and System-Specific Workarounds.Journal of diabetes science and technology · 2026
- Continuous Glucose Monitoring and Automated Insulin Delivery in Infants with Type 1 Diabetes: Real-World Evidence to Support Future International Guidelines.Diabetes technology & therapeutics · 2026