From the paper's conclusion- We acquire data using interleaved PA and multiangle plane wave ultrasound (US) acquisitions measured with a 7.6-MHz linear US array.
Abstract
In this study, we develop vector flow imaging (VFI) techniques for multilayered models with a high wavespeed contrast using photoacoustic (PA) and ultrasonic imaging. Refraction-corrected delay-and-sum (RC-DAS) image reconstruction enforces Snell's law to accurately calculate time delays within each layer. We compare RC-DAS against conventional delay-and-sum (DAS) for VFI in benchtop phantoms made of transparent polymethyl methacrylate (PMMA) in a water bath. The flow of a slow-moving suspension of carbon microspheres (~4 mm/s) beneath a PMMA layer is studied using two phantoms, where the PMMA layer has different shapes and thicknesses. We acquire data using interleaved PA and multiangle plane wave ultrasound (US) acquisitions measured with a 7.6-MHz linear US array. PA waves are generated by a 1064-nm wavelength nanosecond-pulsed laser at 50 Hz, and multiangle plane wave US data are acquired at 100 Hz for 11 steering angles between ±10°. RCDAS improves the flow speed accuracy, reducing the mean absolute error (MAE) by 0.56-0.70 mm/s compared to the theoretical parabolic flow profile. The error in direction estimates improves when we use RC-DAS, with the interdecile range (IDR) reducing by up to 17°. This work emphasizes the importance of refraction correction for accurate flow measurements in layered media with PA and ultrasonic imaging. While both imaging modalities can quantify flow in these multilayered models, the modality best-suited for a specific application will depend on the imaging target and flow dynamics. These techniques show promise for biomedical applications such as intraosseous and transcranial blood flow quantification, and in nondestructive testing (NDT) to monitor fluid motion.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Multi-Frame Reconstruction via Clutter Filtering for Computational Contrast-Enhanced Ultrasound Microflow Imaging.Journal of imaging · 2026
- Real-Time 3-D Volumetric Ultrasonic Imaging of Multilayered Structures Using Phase Shift Migration-Based Depth Extrapolation.IEEE transactions on ultrasonics · 2026
- Time-adaptive particle image velocimetry framework via an event camera under continuous illumination.Optics letters · 2026
- Design of a Multiangle Multidepth Flow Phantom for Ultrasound Flow Calibration.IEEE transactions on ultrasonics · 2026
- Physics-Informed Tensor Velocity Reconstruction From 2-D Velocity Estimates Using Row-Column Probes.IEEE transactions on ultrasonics · 2026
- Virtual-element pixelation for elevation-response recovery in linear-array three-dimensional photoacoustic imagingApplied Physics Letters · 2026