Physics-Informed Tensor Velocity Reconstruction From 2-D Velocity Estimates Using Row-Column Probes.
Lasse Thurmann Jorgensen, Rikke Bannebjerg Baarts, Alexander Cuculiza Henriksen, Michael Bachmann Nielsen, Jorgen Arendt Jensen
Key points
From the paper's conclusion- These results demonstrate that the proposed estimator can accurately and precisely reconstruct tensor velocity fields in clinically relevant and high-velocity flow scenarios.
Abstract
A method is presented for estimating 3-D velocity fields over space-time (tensor velocity fields) by combining 2-D velocity estimates acquired in multiple imaging planes with the continuity equation. The proposed tensor velocity estimator accurately reconstructs flow within the aliasing limit and mitigates motion-related artifacts observed in synthetic aperture (SA) and plane wave imaging (PWI) techniques, which typically reduce estimation accuracy at higher velocities. The estimator is demonstrated using both a short imaging sequence, which estimates the tensor velocity field in a thin volume (effectively a 2-D slice), and a longer sequence for reconstructing flow over a larger volume. A singular value decomposition (SVD) procedure for phase shift noise reduction is also proposed. In addition to improving the estimation precision, the method significantly reduces the required storage space and input size for the reconstruction algorithm: from approximately 20 GB-110 MB in one measurement. Furthermore, the procedure enables quick analysis of the SVD components' contributions to the flow. Flow-rig measurements of parabolic flow were acquired at various combinations of beam-to-flow angles (60°, 75°, and 90°) and flow-rotation angles (50° and 90°), with peak velocities ranging from approximately 10%-95% of the velocity aliasing limit. The average bias for the velocity magnitude was found to be -0.71% $ \pm ~2.96$ %, and the standard deviation (SD) was 0.57% $ \pm ~ 0.19\%$ . From Field II simulations of pulsatile carotid artery flows, the estimator reconstructs the velocity magnitude over a 3.5 s period with a normalized root-mean-square error (nRMSE) of 3.57%. In measurements of flow in a carotid artery phantom, the average velocity magnitude pulse profiles of the mean and peak velocities were estimated with SDs of 0.75% and 2.63%. Similarly, in vivo measurements of the carotid artery bifurcation yielded mean and peak velocity magnitude profiles with estimated SDs of 1.06% and 2.51%. These results demonstrate that the proposed estimator can accurately and precisely reconstruct tensor velocity fields in clinically relevant and high-velocity flow scenarios.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Real-time estimation of high-resolution flow fields and reduced-order coordinates from event-based imaging velocimetry.Experiments in fluids · 2026
- Reconstructing 3D+t Cardiovascular Flow From Sparse Planar Velocity Fields With Neural FieldsarXiv · 2026
- Velocity gradient tensor reconstruction from tracer orientations via Jeffery dynamicsarXiv · 2026
- Low-Rank Tensor Manifolds for Turbulent Field Reconstruction from Sparse DataarXiv · 2026
- Cardiovascular High Frame Rate Echo-Particle Tracking Velocimetry.IEEE transactions on ultrasonics · 2026
- Complex Domain Inverse Problem Formulation for 4D Flow MRI Super-ResolutionarXiv · 2026