Key points
From the paper's conclusion- We propose a method based on combined current-voltage (CCV) measurements performed at high temporal resolution to evaluate performance, stability, and consistency under short-duration (<1 ms) and high-power (>100 W) conditions.
Abstract
Therapeutic ultrasound has been the focus of numerous recent investigations. Recent developments, such as histotripsy techniques, have led to greater electrical solicitation of ultrasound setups with high-intensity and short bursts, which can induce potential risks for patients and operators, as well as suboptimal performances. Neither acoustic nor electrical engineering standards are designed for analyzing such signals. Ultrasound setups are usually characterized by voltage-only (VO) and wattmeter power measurements under long-duration (>1 s) and low-power (<100 W) conditions. We propose a method based on combined current-voltage (CCV) measurements performed at high temporal resolution to evaluate performance, stability, and consistency under short-duration (<1 ms) and high-power (>100 W) conditions. The average power, envelope variation coefficient, and overshoot (OS) factor were computed under various input signal conditions with precise automatic windowing of the active part of the pulse. CCV measurements were validated against wattmeter measurements for long-duration and high-power signals. The instability of a prototype histotripsy setup was characterized to optimize the hardware. Three other ultrasound setups used for histotripsy, high-intensity focused ultrasound (HIFU), and cavitation were evaluated and showed stable behavior. This method can be used to characterize electrical signals across a wide range of ultrasound setups, including setups, in which traditional techniques are inapplicable. In addition, this method provides quantitative information about RF signal instability and is simple to implement. Electrical measurements are less time-consuming than acoustic measurements, so they are essential for optimizing reproducibility in laboratory settings under rigorous conditions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Pulse duration and pulse repetition frequency shape cavitation dynamics and volumetric liquefaction by histotripsy in a fibrous tissue-mimicking phantomScientific Reports · 2026
- Low-duty-cycle pulsed ultrasound for ex vivo liver tissue ablation: thermal safety, lesion conformity, and vascular structure preservation.Biomedical physics & engineering express · 2026
- Ultrasound Exposure May Detrimentally Affect Sperm Function and Survival: Possible Implications for Cryobiology.Reproduction in domestic animals = Zuchthygiene · 2026
- Rapid, Accurate 3-D Localization of Inertial Cavitation Events Using a Large Aperture, Narrowband, Receive-Capable Focused Ultrasound Array.IEEE transactions on ultrasonics · 2026
- Characterization of Bubble Cloud Formation and Tissue Ablation Using a High-Frequency Endoscopic Histotripsy System.Ultrasound in medicine & biology · 2026
- Investigation of High Pulse Repetition Frequency Single-Cycle Histotripsy for Rapid Tissue Ablation.Ultrasound in medicine & biology · 2026