Pulse duration and pulse repetition frequency shape cavitation dynamics and volumetric liquefaction by histotripsy in a fibrous tissue-mimicking phantom
Yashwanth Nanda Kumar, Yak-Nam Wang, Wayne Kreider, Qinghua Han, Jonathan T. C. Liu, Eli Vlaisavljevich, George R. Schade, Adam D. Maxwell
Key points
From the paper's conclusion- These findings show that pulse duration and PRF shape cavitation behavior and liquefaction in this fibrous tissue-mimicking model.
Abstract
Histotripsy is a focused ultrasound technique that mechanically liquefies tissue through cavitation bubble activity and has shown promise for noninvasive tumor ablation. However, treating fibrous, mechanically robust tissues remains challenging, and the influence of pulse parameters on cavitation dynamics and liquefaction efficiency in these tissues is not well understood. Here, we systematically investigated the combined effects of pulse duration and pulse repetition frequency (PRF) on cavitation behavior and lesion formation in a fibrous tissue-mimicking double-network hydrogel. Pulse duration and PRF were varied over four orders of magnitude while maintaining a constant 1% duty cycle. High-speed photographic imaging, shear wave elastography (SWE), B-mode ultrasound, and open-top light-sheet (OTLS) microscopy were used to relate cavitation behavior to phantom damage and liquefaction. The 1-cycle condition produced the largest bubble cloud area at longer exposure times, while the 1 and 10-cycle conditions exhibited higher frame-to-frame correlation and greater spatial persistence. In contrast, longer-pulse, low-PRF exposures (≥ 100 cycles) produced more localized cavitation and contiguous lesion formation. Among the tested parameters, 1,000 -cycle pulses at 10 Hz yielded the highest volumetric liquefaction rates. In contrast, short-pulse, high-PRF conditions generated substantial total damage but little to no fully liquefied volume. These findings show that pulse duration and PRF shape cavitation behavior and liquefaction in this fibrous tissue-mimicking model.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Investigation of High Pulse Repetition Frequency Single-Cycle Histotripsy for Rapid Tissue Ablation.Ultrasound in medicine & biology · 2026
- MRI-based assessment of focused ultrasound parameters on boiling histotripsy lesions in agar-based phantoms.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026
- Characterization of Bubble Cloud Formation and Tissue Ablation Using a High-Frequency Endoscopic Histotripsy System.Ultrasound in medicine & biology · 2026
- Rapid, Accurate 3-D Localization of Inertial Cavitation Events Using a Large Aperture, Narrowband, Receive-Capable Focused Ultrasound Array.IEEE transactions on ultrasonics · 2026
- Histotripsy in tumor therapy: advances in non-thermal mechanical ablation, immune modulation, and clinical translation.Frontiers in immunology · 2026
- Ultrasound-Enhanced Chemical Tissue Clearing of Large Specimens for 3D Microscopy: A Rapid and Accessible Method Using Standard Laboratory Equipment.Methods and protocols · 2026