Iterative Reconstruction Performance on the NeuroEXPLORER: Evaluation with Static and Dynamic Human Imaging.
Yifan Hu, Jiazhen Zhang, Jean-Dominique Gallezot, Tommaso Volpi, Tianyi Zeng, Takuya Toyonaga, Richard E Carson
Department of Radiology and Biomedical Imaging, Yale University, Connecticut, USA. · Department of Biomedical Engineering, Yale University, Connecticut, USA.
Key points
From the paper's conclusion- This work evaluated the impact of iterative reconstruction on the quantitative performance of NX using human 18F-SynVesT-1 and 11C-PHNO data with an injection dose of 167.2 ± 13.6 MBq and 275.7 ± 64.8 MBq, respectively.
Abstract
The NeuroEXPLORER (NX) is a next-generation, brain-dedicated PET scanner offering 10× higher sensitivity compared to the HRRT and < 2 mm spatial resolution. This work evaluated the impact of iterative reconstruction on the quantitative performance of NX using human 18F-SynVesT-1 and 11C-PHNO data with an injection dose of 167.2 ± 13.6 MBq and 275.7 ± 64.8 MBq, respectively. Both 100% count level and 20% down-sampled count level were evaluated. Images were reconstructed with ordered-subsets expectation maximization incorporated PSF and TOF (PSF-TOF-OSEM) using 5 subsets and up to 20 iterations. Quantitative performance of static imaging was evaluated by computing bias and noise from statistically independent list-mode replicates. Simulations incorporating iteration-dependent bias and noise of each dynamic frame were used to evaluate effects on kinetic parameters. In static imaging, 5 subsets × 10 iterations achieved ROI bias < 10% and noise < 1% for 18F-SynVesT-1, and bias < 10% with noise < 10% for 11C-PHNO. In dynamic imaging simulation, with 5 subsets and 15 iterations, kinetic parameter bias remained < 20% and noise < 5%. The results demonstrate quantitative stability and precision of NX across tracers and count levels.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Exceptional brain PET images from the NeuroEXPLORER: scans with targeted radiopharmaceuticals and comparison to HRRTEuropean Journal of Nuclear Medicine and Molecular Imaging · 2025
- Design and Development of NeuroSphere PET: A Next-Generation 7-T MR-Compatible Dedicated Brain PET Scanner.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2026
- Kinematic Total-Body PET Video Reconstruction via Hierarchical List-Mode EM and Validation-Adaptive Space-Time RegularisationarXiv · 2026
- Characterization and Initial Optimization of Reconstruction Performance for Detector Crosstalk of Ultrahigh Performance Brain PET Imager.IEEE transactions on radiation and plasma medical sciences · 2026
- A harmonisation framework for multi-centre preclinical PET imaging across a national research infrastructure.Physics in medicine and biology · 2026
- NA-DIP: A Noise-Aware Deep Image Prior for Generating Dedicated Brain PET-Quality Images from Whole-Body PET Acquisitions.NeuroImage · 2026