NA-DIP: A Noise-Aware Deep Image Prior for Generating Dedicated Brain PET-Quality Images from Whole-Body PET Acquisitions.
Chenyang Han, Andrew T Trout, Andi Li, Joseph G Meier, Cara E Morin, Adam F Prasanphanich, Susan E Sharp, Christopher G Anton,
Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, USA, 45219. Electronic address: hancg@mail.uc.edu. · Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA, 45229; Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA, 45267; Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, OH, USA, 45267. Electronic address: andrew.trout@cchmc.org.
Key points
From the paper's conclusion- NA-DIP enhanced brain PET images from whole-body acquisitions demonstrated good quantitative agreement and image quality comparable to or exceeding the reference, supporting the feasibility of eliminating separate dedicated brain scans.
Abstract
PURPOSE: To generate dedicated brain PET-quality images from routine whole-body PET acquisitions by robustly enhancing the brain region using a noise-aware deep image prior (NA-DIP) approach. METHODS: NA-DIP integrates anatomy-guided priors derived from patient-specific μ-maps or MR images, a regularization strategy for enhanced denoising, and a variance-based early stopping criterion that adaptively monitors noise without requiring prior noise assumptions. Using noisy PET images as self-supervised targets, the method was first evaluated using simulation data spanning three noise levels to investigate the trade-off between noise suppression and bias. It was then applied to brain images extracted from 90-s-per-bed-position whole-body acquisitions from 15 pediatric FDG-PET studies spanning a broad range of patient demographics, physiological variability, and image noise levels. Using the corresponding 360-s-per-bed-position dedicated brain scans as the reference, NA-DIP-enhanced images were evaluated for noise reduction, standardized uptake value (SUV) accuracy, and image quality in a blinded reader study. RESULTS: NA-DIP demonstrated a superior noise-bias trade-off compared with Gaussian filtering and conventional DIP stopping strategies, particularly under high-noise conditions. The inclusion of MR or μ-map guidance further improved performance. Across pediatric patients, NA-DIP-enhanced 90-s images exhibited lower noise than the corresponding 360-s dedicated brain images while showing modest variability in SUV measurements. Blinded readers rated the NA-DIP-enhanced images as comparable to or better than dedicated brain images in most cases. CONCLUSION: NA-DIP enhanced brain PET images from whole-body acquisitions demonstrated good quantitative agreement and image quality comparable to or exceeding the reference, supporting the feasibility of eliminating separate dedicated brain scans.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Anatomically and biochemically guided deep image prior for sodium MRI denoisingComputerized Medical Imaging and Graphics · 2026
- Acquisition time/dose reduction in pediatric PET imaging using patch-based deep learningEJNMMI Physics · 2026
- A rapid total-body PET imaging approach for pediatric patients using non-attenuation-corrected PET scansEJNMMI Physics · 2026
- Patlak-Guided Self-Supervised Learning for Dynamic PET Denoising.IEEE transactions on radiation and plasma medical sciences · 2026
- Deep progressive reconstruction for low-dose ¹⁸F-FDG PET/CT imaging in pediatric patients.Annals of nuclear medicine · 2026
- Impact of depth-of-interaction and spatially-variant point-spread-function model on the performance of ultra-high resolution brain PET.Physics in medicine and biology · 2026