STRIDE: A Flexible, Depth-Controlled Intramuscular EMG Platform for Small-Animal Studies.
Morgan Riley, Ant Lakatos, Benjamin C Johnson
Key points
From the paper's conclusion- We introduce STRIDE (Stable Targeted Recording, Intramuscular Depth-controlled Electromyography), a flexible printed-circuit array with depth stops and selectable cross- and down-fiber bipolar pairings.
Abstract
Reliable electromyography (EMG) recording can substantially improve closed-loop neuromodulation workflows by providing timely feedback on muscle recruitment. Conventional EMG needles limit intramuscular EMG recordings through placement variability, motion sensitivity, and inconsistent SNR. We introduce STRIDE (Stable Targeted Recording, Intramuscular Depth-controlled Electromyography), a flexible printed-circuit array with depth stops and selectable cross- and down-fiber bipolar pairings. In vivo in the mouse hindlimb, we compared STRIDE to EMG needles during non-selective sciatic electrical stimulation and physiological toe-pinch. Arrays were implanted at mid-belly using the depth stop and verified post-hoc by micro-computed tomography. Within a single muscle, STRIDE recordings produced lower baseline noise and higher SNR than the needle, despite the needle's larger compound muscle action potential amplitude. Frequency spectra showed reduced line and broadband interference on STRIDE channels. Concurrent recordings from four muscles in a mouse hind limb at identical stimulation amplitudes revealed a tibial-leaning recruitment profile at maximal drive, consistent with branch anatomy and array placement. During physiological toe-pinch, artifactcontrolled analysis showed that STRIDE captured more array-level event times than the single bipolar needle channel and yielded two to three recurring waveform classes per STRIDE channel, supporting broader multi-site sampling of putative physiological EMG activity. Furthermore, STRIDE required no reinsertions, whereas the needles required many. STRIDE also exhibited higher axial retention, and landed within the intended depth-stop increment, supporting depth-guided and stable implantation in this study. STRIDE provides a more stable, multi-site intramuscular high-density EMG recording platform and, in this acute comparison, achieved improved practical SNR consistent with contributions from recording geometry and reduced baseline noise beyond raw amplitude alone. Our platform supports multi-muscle readouts for neuromuscular physiology, mapping, and future closed-loop applications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Selective activation of nerve fiber subpopulations with intrafascicular stimulation.Journal of neural engineering · 2026
- Opto-Myomatrix: μLED Integrated Microelectrode Arrays for Optogenetic Activation and Electrical Recording in Muscle TissueIEEE Transactions on Biomedical Engineering · 2026
- State- and Identity-Dependent Motor Neuron Excitability Shapes Cutaneous Long-Latency Reflexes.Journal of neurophysiology · 2026
- A method of compensating for the excitability of spinal motoneurones when estimating the magnitude of potentials evoked in skeletal musclesThe Journal of Physiology · 2026
- Early electrical stimulation promotes functional recovery after volumetric muscle loss.Acta biomaterialia · 2026
- Acute Stimulation Selectivity of Minimally Invasive Interfascicular Nerve Stimulation (MIINS) in a Large Animal Model (June 2026).IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2026