Reliability and Agreement of CMAP Scan-Derived MUNE Algorithms in Healthy Individuals.
Tarun Arora, Mohammed Almokdad, Daniel M Sorensen, Agessandro Abrahao, Abir Alaamel, Halil C Alaydin, Martin Ballegaard, Evren Boran,
Key points
From the paper's conclusion- CMAP scan MUNE methods showed limited test-retest measurement properties in healthy individuals. Variability reflected contributions from both CMAP acquisition and algorithm-based estimation.
Abstract
OBJECTIVE: CMAP scan-based motor unit number estimation (MUNE) methods offer non-invasive, physiologically meaningful measures of motor unit integrity. This study evaluated and compared the test-retest measurement properties of three algorithms: STEPIX, CDIX, and StairFit, with comparison to previously published MScanFit values. METHODS: MUNE was estimated from the abductor pollicis brevis (APB), abductor digiti minimi (ADM), and tibialis anterior (TA) muscles in 148 healthy adults recruited across 15 international sites. Relative reliability was assessed using intraclass correlation coefficient (ICC) and concordance correlation coefficient (CCC). Agreement was evaluated using Bland-Altman analysis and estimation statistics. Absolute measurement error was quantified using the standard error of measurement (SEM), SEM%, and smallest detectable changes (SDC). Sensitivity analyses were performed after excluding site- or participant-level data that exceeded quality control thresholds. RESULTS: Across all muscles and algorithms, relative reliability was poor-to-moderate (ICC: 0.29-0.76), with SEM% values of 12-29%. CDIX demonstrated the lowest reliability and highest measurement error, while StairFit and STEPIX performed comparably. CMAP peak amplitude showed moderate-to-good relative reliability (ICC: 0.73-0.82) with SEM% values of 12-16%. Sensitivity analyses improved CMAP peak reliability, but produced only modest changes in MUNE measurement properties. Percent-change analyses indicated that visit-to-visit CMAP peak variability contributed to MUNE variability, but the strength of this association differed across algorithms. CONCLUSION: CMAP scan MUNE methods showed limited test-retest measurement properties in healthy individuals. Variability reflected contributions from both CMAP acquisition and algorithm-based estimation. SIGNIFICANCE: No algorithm consistently achieved the combined reliability, precision, and SDC values needed for tracking individual-level change under the conditions studied. Future studies should evaluate whether measurement properties improve in clinical populations with motor unit loss.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Physiological robustness of MScanFit to simulated motor unit loss and remodellingbioRxiv · 2026
- A revised motor unit number estimate detects presymptomatic motor neuron loss in amyotrophic lateral sclerosis.Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology · 2026
- Direct measurement of motor unit twitch properties using routine clinical ultrasound and optical flowmedRxiv · 2026
- Feasibility and within-session repeatability of motor-unit decomposition using high-density surface electromyography in women with chemotherapy-induced peripheral neuropathy.Physical and engineering sciences in medicine · 2026
- Beyond snapshots: A dynamic framework for continuous motor unit tracking to enhance neurophysiological assessments.bioRxiv : the preprint server for biology · 2026
- EMG Probability Density Function Inverse Problem: Motor Unit Potential Amplitude Versus Motor Unit Recruitment Threshold Maps.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2026