Direct measurement of motor unit twitch properties using routine clinical ultrasound and optical flow
S. Maitland, J. Scott, K. Suetterlin, R. G. Whittaker
Key points
From the paper's conclusion- A motor unit twitch index was measurable in 32/49 recordings: 14.4 in ADM, 14.9 in APB and 18.6 in TA.
Abstract
Introduction/Aims Current motor unit assessment techniques overlook the mechanical output that underpins function and are limited: surface recordings are weighted to the superficial ~1cm and needle EMG to a ~2 mm radius. We investigated whether clinical muscle ultrasound can measure motor unit twitches directly. Methods Peripheral nerve stimulation targeted abductor digiti minimi (ADM), abductor pollicis brevis (APB) and tibialis anterior (TA). Stimulus intensity was set 10% above supramaximal and decreased in 0.01-0.05 mA steps until the Compound Muscle Action Potential (CMAP) was abolished. An 18 MHz transducer was placed transverse to the muscle, co-located with the active electrode, with video time-locked to each stimulus. Inter-frame motion was quantified using Farneback optical flow, and twitch/CMAP amplitudes compared to derive mechanical and electrical activation thresholds and a motor unit twitch index. Results We obtained 66 recordings from 22 participants (11 female, 21-63 years); 49 met prespecified quality criteria. Threshold medians (CMAP versus ultrasound) were 6.84/5.82 mA in ADM, 5.28/4.84 mA in APB and 10.34/9.83 mA in TA. The ultrasound threshold was lower than the CMAP threshold in all three muscles (ADM +0.27 mA, p = 0.009; APB +0.08 mA, p = 0.001; TA +0.21 mA, p = 0.011). A motor unit twitch index was measurable in 32/49 recordings: 14.4 in ADM, 14.9 in APB and 18.6 in TA. Median contraction/half-relaxation times for ADM, APB & TA were 80/80, 88/95 and 79/103 ms respectively; trial-to-trial variability was 5.3/8.3 ms. Discussion Clinical ultrasound can be used to directly measure clinically relevant twitch parameters such as twitch amplitude which recruits in parallel with CMAP and is not detectable with conventional clinical neurophysiology techniques. Mechanical activation is detected at slightly lower stimulus currents than the CMAP, and the twitch signal plateaus before the CMAP does; neither effect was confined to the larger muscle.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Muscle activation assessment using ultrasound time-harmonic elastography and tonic vibration reflexJournal of Biomechanics · 2026
- Comparison between ultrasound and electromyography for detection of fasciculations in amyotrophic lateral sclerosis: an updated systematic review and meta-analysis.Radiologia brasileira · 2026
- Comparative Analysis of Muscle Fascia Tracking Algorithms for Real-Time Muscle Monitoring using Wearable Ultrasound.IEEE journal of biomedical and health informatics · 2026
- Beyond snapshots: A dynamic framework for continuous motor unit tracking to enhance neurophysiological assessments.bioRxiv : the preprint server for biology · 2026
- In Vivo Dispersion Sensing Using Wearable Ultrasound Shear-Wave Elastometry.IEEE transactions on ultrasonics · 2026
- EMG Probability Density Function Inverse Problem: Motor Unit Potential Amplitude Versus Motor Unit Recruitment Threshold Maps.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2026