Bias-Switchable Row-Column Array Imaging Using Fast Orthogonal Row-Column Electronic Scanning (FORCES) Compared With Conventional Row-Column Array Imaging.
Randy N Palamar, Mohammad Sobhani, Darren Dahunsi, Negar Majidi, Afshin Kashani Ilkhechi, Joy Wang, Jeremy Brown, Roger Zemp
Department of Electrical and Computer Engineering, University of Alberta, Edmonton, AB T6G 2R3, Canada. · School of Biomedical Engineering, Dalhousie University, Halifax, NS B3H 4R2, Canada.
Key points
From the paper's conclusion- This study aims to provide such a comparison, demonstrating superior B-scan and volumetric images from two electrostrictive relaxor TOBE arrays, using a method called Fast Orthogonal Row-Column Electronic scanning (FORCES), compared to conventional RCA imaging schemes, including Tilted Plane Wave (TPW) compounding and Virtual Line Source (VLS) imaging.
Abstract
Row-Column Arrays (RCAs) offer an attractive alternative to fully wired 2D-arrays for 3D-ultrasound, due to their greatly simplified wiring. However, conventional RCAs face challenges related to their long elements. These include an inability to image beyond the shadow of the aperture and an inability to focus in both transmit and receive for desired scan planes. To address these limitations, we recently developed bias-switchable RCAs, also known as Top Orthogonal to Bottom Electrode (TOBE) arrays. These arrays provide novel opportunities to read out from every element of the array and achieve high-quality images. While TOBE arrays and their associated imaging schemes have shown promise, they have not yet been directly compared experimentally to conventional RCA imaging techniques. This study aims to provide such a comparison, demonstrating superior B-scan and volumetric images from two electrostrictive relaxor TOBE arrays, using a method called Fast Orthogonal Row-Column Electronic scanning (FORCES), compared to conventional RCA imaging schemes, including Tilted Plane Wave (TPW) compounding and Virtual Line Source (VLS) imaging. The study quantifies resolution and Generalized Contrast to Noise Ratio (gCNR) in phantoms, and also demonstrates volumetric acquisitions in phantom and animal models.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Angular-first channel-domain delay-multiply-and-sum beamforming with dual coherence for row-column array-based 3D power Doppler imaging.Ultrasonics · 2026
- Compound Lens Design and Beamforming for Wide-Field Volumetric Imaging Using a Row-Column Array.IEEE transactions on ultrasonics · 2026
- Volumetric Tissue Organization Mapping Using Backscatter Tensor Imaging With a Row Column Addressing Transducer.Ultrasound in medicine & biology · 2026
- Real-Time 3-D Volumetric Ultrasonic Imaging of Multilayered Structures Using Phase Shift Migration-Based Depth Extrapolation.IEEE transactions on ultrasonics · 2026
- Microbeamformer-aware layout optimization of a 2D intracardiac echocardiography array for grating-lobe suppression.Ultrasonics · 2026
- 512 + 512 Anodically Bonded Row-Column Addressed CMUT Array Fabrication and Characterization.IEEE transactions on ultrasonics · 2026