Development and Bench-to-Human Feasibility Evaluation of a Wireless Pinch-and-Grip Dynamometer.
Ali Pourhossein, Mohamed Mehdi Ouerghi, Elisabeth Kuborn, Doguhan Tasdemir, Viktor Warwas, Charmayne Mary Lee Hughes
Faculty V-Mechanical Engineering and Transport Systems, Institute of Psychology and ErgonomicsTechnische Universität Berlin Berlin 10623 Germany.
Key points
From the paper's conclusion- The MeRKeL system enables accurate and repeatable, reference-calibrated wireless measurement of pinch and grip strength, establishing a robust technical foundation for subsequent clinical evaluation and future home-based neuromuscular monitoring studies.
Abstract
OBJECTIVE: This study presents MeRKeL, a portable wireless system designed for quantitative, reference-calibrated assessment of pinch and grip strength, and evaluates its technical validity and human feasibility under standardized laboratory conditions. METHODS: The system consists of two compact and functionally aligned modules (pinch and grip dynamometer) sharing a unified electronic architecture and data acquisition pipeline. Both employ task-specific mechanical designs tailored to the distinct loading characteristics of pinch and grip actions. Reference-based calibration and bench validation were performed across the full operating ranges and across multiple units. Accuracy, agreement, and within-session repeatability were evaluated using root mean squared error (RMSE), Bland-Altman analysis, and intraclass correlation coefficient (ICC). Feasibility testing in 196 healthy adults examined associations between maximal strength and demographic, behavioral, and health-related variables. RESULTS: Bench validation showed high agreement with the calibrated reference instrument (pinch: RMSE = 0.95 N, bias = -0.56 N; grip: RMSE = 1.86 N, bias = -1.10 N), and within-session repeatability was excellent (MDC95 pinch = 0.86 N; grip = 1.43 N). Experimental testing reproduced expected associations with key demographic and behavioral factors. CONCLUSION: The MeRKeL system enables accurate and repeatable, reference-calibrated wireless measurement of pinch and grip strength, establishing a robust technical foundation for subsequent clinical evaluation and future home-based neuromuscular monitoring studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Digital handgrip assessment in musculoskeletal health: reliability, measurement precision, interchangeability, and clinical implications for rehabilitation and sports medicineBMC Sports Science, Medicine and Rehabilitation · 2026
- Development, Calibration and Metrological Characterization of a Low-Cost 3D Printed Handgrip Dynamometer Based on Force-Sensing Resistor TechnologyMetrology · 2026
- Test-Retest Reliability of Hierarchical Proprioception Assessment of the WristmedRxiv · 2026
- Design and statistical validation of low-cost electrogoniometers for elbow orthosis applications.Biomedical physics & engineering express · 2026
- Portable Dynamometry Is Reliable for Measuring Knee and Ankle Strength in Daily Practice: Results From a Systematic Review With Meta-analysis and Evidence Gap Map Using the COSMIN Methodology.The Journal of orthopaedic and sports physical therapy · 2026
- Pilot validation of a piezo‑resistive gnathodynamometer for maximum voluntary bite force measurement in adults: a cross sectional comparative study.BMC oral health · 2026