PCG-to-ECG Signal Reconstruction Using Conditional GAN with Multi-Scale Attention.

Zafar Ahmad, Nazia Perwaiz, Muhammad Salman Khan, Sidra Sultana, Fatima Abdullah, Hamza Anjum, Izharul Haq

Computational

Key points

From the paper's conclusion
  • A matched component ablation shows that the multi-scale attention drives the gain, and that the adversarial term does not improve the measured metrics. We recommend reporting R-peak amplitude error and QRS-width error alongside PSNR and SSIM.

Abstract

OBJECTIVE: ECG recording requires adhesive skin electrodes and trained staff, so long-term ambulatory monitoring is difficult. We reconstruct electrocardiogram (ECG) signals from phonocardiogram (PCG) recordings as a step toward approximate, electrode-free cardiac-cycle timing. METHODS: We train a conditional generative adversarial network (cGAN). The generator is a U-Net with multi-head self-attention and multi-scale dilated convolutions, paired with a spectrally normalized PatchGAN discriminator. A polarity-aware step corrects inverted ECG waveforms. We compare four architectures on 453 segments from the EPHNOGRAM dataset (8 kHz). RESULTS: Among four architectures evaluated under one protocol, the proposed model leads on all metrics except SSIM. It reaches 17.10 dB PSNR, 0.903 SSIM, 0.610 correlation, and 0.126 R-peak amplitude error. Temporal R-peak detection reaches 0.694 F1 at $\pm$50 ms and 0.773 F1 at $\pm$150 ms. The PCG-only baseline reaches 0.404 and 0.529. A subject-clustered 95 % confidence interval for correlation spans [0.314, 0.907] across three test recordings. A Tanh output layer cuts R-peak gradients by 10-80× and clips R-peaks that PSNR and SSIM fail to flag. CONCLUSIONS: A matched component ablation shows that the multi-scale attention drives the gain, and that the adversarial term does not improve the measured metrics. We recommend reporting R-peak amplitude error and QRS-width error alongside PSNR and SSIM. SIGNIFICANCE: On EPHNOGRAM, the reconstructed ECG gives approximate cardiac-cycle timing under matched recording hardware, not a diagnostic ECG replacement. A blind cross-dataset test shows that it does not transfer to new hardware without retraining.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

PCG-to-ECG Signal Reconstruction Using Conditional GAN with Multi-Scale Attention — Science Skim