European Heart Journal

Synthetic ECG-guided temporal gating improves paediatric murmur grading, timing, and shape classification on the CirCor DigiScope dataset

Z Ahmad, N Perwaiz, S Khan, S Sultana, I Haq

Computational · n=942

Key points

From the paper's conclusion
  • We compared two ECG-gated classifiers against a PCG-only 2D convolutional neural network with self-attention on 3,163 CirCor DigiScope recordings from 942 paediatric patients (age 0–21, 54% male): a multilayer perceptron (MLP) and a random forest (RF), both under stratified 10 and 5-fold cross-validation.

Abstract

Background/ Introduction Non-invasive murmur detection from phonocardiograms (PCG) has advanced, but detection answers only whether a murmur is present, not how severe it is or what to do next. Cardiologists also need to know: what grade, what timing, and what shape? As target pathologies increase in number, their acoustic content overlaps within the 20–500 Hz PCG bandwidth. In-band noise occupies the same frequency range, so frequency-based denoising cannot separate artefacts from diagnostic content. Grading accuracy on the CirCor DigiScope benchmark reaches only about 52%. Characterisation needs temporal localisation of murmur energy within the cardiac cycle, but single-channel PCG gives no timing anchor for phase boundaries. Purpose We tested whether a synthetic electrocardiogram (ECG), reconstructed from PCG, can gate each cardiac cycle into phase-specific windows and support murmur grading, timing, and shape classification from a single acoustic sensor. Methods We trained a deep learning model (Pix2Pix conditional generative adversarial network) to synthesise ECG from PCG spectrograms using 2,267 paired PCG-ECG cycles from 23 healthy adult EPHNOGRAM subjects. From synthetic-ECG R-peaks, we divided each cardiac cycle into four phases by fixed ratios: S1 (0–15%), systole (15–50%), S2 (50–60%), and diastole (60–100%) and computed 464 temporal, spectral, and morphological features per phase. We compared two ECG-gated classifiers against a PCG-only 2D convolutional neural network with self-attention on 3,163 CirCor DigiScope recordings from 942 paediatric patients (age 0–21, 54% male): a multilayer perceptron (MLP) and a random forest (RF), both under stratified 10 and 5-fold cross-validation. Results ECG reconstruction reached 0.903 structural similarity (SSIM) and 95.4% R-peak detection F1-score. Compared with the PCG-only baseline, ECG-gated classification improved all characterisation metrics (paired t-tests across 10 folds): grading accuracy increased from 67.4% to 74.0% (p = 0.008), timing from 68.4% to 72.9% (p = 0.011), and shape from 58.8% to 70.6% (p < 0.001). Detection accuracy decreased from 93.4% to 90.3% (p = 0.042), expected given the 6.9-fold shorter gated window (580 ms versus 4,000 ms baseline). An ablation that replaced ECG-gated boundaries with equal-time segmentation on the same feature set showed that temporal alignment drives the gain: MLP characterisation accuracy dropped to 45.6–50.8% without phase-gated boundaries (all p < 10⁻⁴, paired t-test). Conclusions Temporal gating through synthetic ECG improves characterisation accuracy by 4.5–11.8 percentage points over the PCG-only baseline. This approach could let a single PCG sensor extract murmur grade, timing, and shape for bedside screening in settings without echocardiography. We recommend prospective validation against echocardiographic diagnosis.Results comparison tableCore methodology

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers