Utilization of Cone Beam CT for the Measurement of Peri-Implant Bone Graft Density Following Lateral Sinus Augmentation.
Ali H Abbas Alhussaini, Thair A Hassan, Salah Abdalmehdi Ismael
Department of Oral and Maxillofacial Surgery, College of Dentistry-Alturath University. · Chairman of the Scientific Council of Maxillofacial Surgery in the Iraqi Board for Medical Specializations, Baghdad, Iraq.
Key points
From the paper's conclusion- The study groups B and C did not significantly improve the graft density in comparison to group A at T2. The use of cone beam computerized tomography is valuable for the measurement of graft density after maxillary sinus augmentation.
Abstract
BACKGROUND: Bone remodeling after tooth extraction and maxillary sinus pneumatization often creates a clinical challenge for dental implant placement in the posterior maxilla. AIM: To evaluate the changes in graft density after 1-stage lateral sinus augmentation utilizing deproteinized bovine bone alone or mixed with platelet-rich fibrin. MATERIALS AND METHODS: Twenty-five patients, ages ranged from 25 to 72 years, met the eligibility criteria. A total of 34 lateral sinus augmentation procedures were performed utilizing bone graft and 50 simultaneously installed dental implants. The lateral sinus augmentation cases were allocated randomly into 3 groups: group A, utilizing solely deproteinized bovine bone. Group B, using deproteinized bovine bone mixed with leukocyte and platelet-rich fibrin. Group C, using deproteinized bovine bone mixed with advanced platelet-rich fibrin. The graft density was measured at baseline (T1) and after 24 weeks (T2). Cone beam computerized tomography was obtained for the measurement of changes in graft density for all groups. RESULTS: There was an increase in mean peri-implant graft density from T1 to T2 for each study group; however, it did not reach the statistical significance difference level (P˃0.05). Furthermore, there was no statistically significant increase in graft density for both study groups B and C versus group A after 24 weeks. CONCLUSIONS: The study groups B and C did not significantly improve the graft density in comparison to group A at T2. The use of cone beam computerized tomography is valuable for the measurement of graft density after maxillary sinus augmentation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative evaluation of bone density after implant placement with and without bone grafting using CBCT.Bioinformation · 2026
- Defect-Adapted Guided Bone Regeneration of the Atrophic Edentulous Maxilla Using a PRGF-Enriched Autogenous Bone/ABBM Composite: A Prospective One-Year Case Series.Materials (Basel, Switzerland) · 2026
- Horizontal ridge augmentation in maxillary esthetic zone using bovine bone graft versus extended sticky bone with simultaneous implant placement: a randomized clinical study.BMC oral health · 2026
- Comparative Evaluation of Concentrated Growth Factor and Platelet-rich Fibrin on Healing of Periapical Lesions using Cone Beam Computed Tomography - An In Vivo Study.International journal of applied & basic medical research · 2026
- Effect of Osseodensification on Ridge Expansion and Bone Density for Implant Placement in the D3 and D4 Bone of the Posterior Maxilla: A Comparative Study.Cureus · 2026
- Radiographic evaluation of the impact of hyaluronic acid and bone graft on peri-implant tissue: A randomized clinical trial.Wiadomosci lekarskie (Warsaw, Poland : 1960) · 2026