Pseudarthrosis and breakage of a short cephalomedullary nail following an intertrochanteric fracture: a case report.
Guillem Fernandez Gil, John McManus, Matthias Vautrin
Department of Musculoskeletal System, Service of Orthopaedic Surgery and Traumatology, Lausanne University Hospital (CHUV), Lausanne, Switzerland. · Department of Orthopaedic Surgery and Traumatology, Groupement Hospitalier de l'Ouest Lémanique (GHOL), Nyon, Switzerland.
Key points
From the paper's conclusion- Implant breakage after cephalomedullary nailing is a rare but potentially catastrophic complication associated with delayed union and nonunion. Early recognition of delayed fracture healing and timely surgical intervention are essential to prevent fatigue failure of the implant and to improve patient outcomes.
Abstract
INTRODUCTION AND IMPORTANCE: Cephalomedullary nailing is the standard treatment for intertrochanteric fractures. Implant breakage is a rare but serious complication, typically associated with delayed union or nonunion. PRESENTATION OF CASE: We report the case of a 77-year-old man with a history of myelofibrosis who sustained an intertrochanteric femoral fracture treated with a short cephalomedullary nail. During follow-up, the patient developed persistent pain and functional limitation. Delayed union was confirmed at 4 months postoperatively, based on persistent symptoms and lack of radiologic healing on CT. Shortly thereafter, he presented with acutely worsening pain, and radiographs revealed fracture of the nail at the proximal aperture for the lag screw, a known stress concentration zone. The patient underwent hardware removal and conversion to total hip arthroplasty. Postoperative recovery was favorable, with progressive return to full function and absence of pain at follow-up. CLINICAL DISCUSSION: Implant breakage is typically a consequence of mechanical fatigue in the context of delayed union or nonunion. Several factors may contribute, including suboptimal fracture reduction, insufficient medial cortical support, and prolonged mechanical loading. CONCLUSION: Implant breakage after cephalomedullary nailing is a rare but potentially catastrophic complication associated with delayed union and nonunion. Early recognition of delayed fracture healing and timely surgical intervention are essential to prevent fatigue failure of the implant and to improve patient outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Intramedullary Nailing of Femoral Shaft Fractures: Implications of Interlocking Screw Breakage.Cureus · 2026
- Peri-Implant Subcapital Femur Fracture Post Cephalomedullary Nail Fixation.Case reports in orthopedics · 2026
- Intramedullary Femoral Nailing-Blade Versus Screw: A Risk Analysis of Implant-Related Complications in Trochanteric Femoral Fractures.Journal of clinical medicine · 2026
- Postoperative lateral-wall status and fixation failure after cephalomedullary nailing of extracapsular hip fractures: an ambispective cohort study.Frontiers in medicine · 2026
- Failure of intramedullary nailing in pertrochanteric femur fractures - A retrospective analysis of 383 patients over a 5.5-year period.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2026
- Helical Blade Versus Lag Screw Fixation in Cephalomedullary Nailing of Unstable Trochanteric Fractures: A Narrative Review.Cureus · 2026