Efficacy, Efficiency, and Safety of a Poly-L-lactic Acid Cuff Tube Assisting for Microvascular Anastomosis.
Yucheng Qiu, Hui Su, Jing Luo, Yue Zhang, Jun Yang, Xianyu Zhou, Yumei Zhang
. Department of Plastic and Reconstructive Surgery, Shanghai Jiao Tong University School of Medicine Affiliated with the Ninth People's Hospital, Shanghai 200011, China. · . State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620, China.
Key points
From the paper's conclusion- PLLA cuff tube is a safe and effective alternative to traditional hand-sewn method, with strong potential for clinical application in microvascular anastomosis.
Abstract
BACKGROUND: Vascular anastomosis is a cornerstone of microsurgery. Anastomosis time and vessel patency significantly influence surgical success. The disadvantages of the traditional hand-sewn method requires a high technical threshold, prolonged surgical time, and an increased risk of vessel occlusion or leakage. Consequently, developing a reliable device to facilitate vascular anastomosis is essential in microsurgery. METHODS: In this study, a poly-L-lactic acid (PLLA) cuff tube with favorable mechanical and biological properties was employed for anastomosis using a nonsuture cuff technique. Its biocompatibility was comprehensively evaluated in vitro. Its surgical feasibility was validated in vivo using a rat syngeneic orthotopic hindlimb transplantation model. Vessel patency and anastomotic time were documented, and histopathological analysis was performed. RESULTS: Both L929 cells viability assay and mammalian chromosomal aberration test showed that the PLLA cuff tubes were noncytotoxic. The mean time of anastomosing a single vessel was 18.9 min using the cuff tube compared with 28.8 min using the hand-sewn method. All vessels remained patent in the cuff technique group, while 3 cases of total occlusion occurred in the hand-sewn group. Histopathological analysis revealed no obvious signs of inflammation or immune response associated with PLLA cuff tube implantation. CONCLUSIONS: PLLA cuff tube is a safe and effective alternative to traditional hand-sewn method, with strong potential for clinical application in microvascular anastomosis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Novel Intraluminal Microtube Anastomosis System (IMAS) for Rapid Rat Microvascular Reconstruction: Development and Experimental Evaluation.Journal of clinical medicine · 2026
- SilMA-stabilized micro-wavy PLCL vascular grafts for native-like nonlinear mechanics and vascular remodeling.Colloids and surfaces. B, Biointerfaces · 2026
- Everter-Assisted Arterial Coupling in Abdominal-Based Breast Reconstruction: A Preclinical Study and Retrospective Feasibility Case Series.Cancers · 2026
- Reperfused human umbilical cords: hydrodynamic and hemolytic analysis of the ex vivo model for umbilical cord ECMO cannulation.Frontiers in bioengineering and biotechnology · 2026
- Coupler-assisted Versus Hand-sewn Venous Anastomosis in Deep Inferior Epigastric Perforator Flap Breast Reconstruction: A Single-institution Study.Plastic and reconstructive surgery. Global open · 2026
- A "Vascular Band-Aid" strategy for proactive inhibition of post-anastomotic vascular complications.Regenerative biomaterials · 2026