Coupler-assisted Versus Hand-sewn Venous Anastomosis in Deep Inferior Epigastric Perforator Flap Breast Reconstruction: A Single-institution Study.
Marlene Schelletter, Edward T C Dong, Salvatore Giordano, Gauthier Zinner, Carlo M Oranges
From the Department of Plastic, Reconstructive and Aesthetic Surgery, Geneva University Hospitals, Geneva University, Geneva, Switzerland. · Department of Plastic and General Surgery, Turku University Hospital and The University of Turku, Turku, Finland.
Key points
From the paper's conclusion- Venous coupler-assisted anastomosis in DIEP flap breast reconstruction does not increase postoperative complication rates and offers significant time reduction in both ischemia time and overall operative time. Given its reliability and efficiency, the microvascular coupler can safely be incorporated into DIEP flap breast reconstruction.
Abstract
BACKGROUND: Venous anastomosis remains a critical step in achieving successful free flap transfer. The venous coupler device has gained popularity due to its technically less demanding and time-efficient application. Although several retrospective and multicenter studies have evaluated coupler-assisted venous anastomosis in deep inferior epigastric perforator (DIEP) flap breast reconstruction, evidence remains heterogeneous. This study aims to compare mechanically performed versus hand-sewn venous anastomosis in DIEP flap breast reconstruction. METHODS: We retrospectively included patients who underwent unilateral or bilateral DIEP flap breast reconstruction following oncologic mastectomy between January 2018 and June 2024. We divided the patient cohort into 2 groups: coupler-assisted group and hand-sewn group. The primary outcome was the free flap ischemia time, and secondary outcomes included postoperative donor- and recipient-site complications. RESULTS: A total of 114 patients were included in this study, encompassing 141 DIEP flap breast reconstructions. This corresponds to 76 (53.9%) DIEP flap breast reconstructions performed using a venous coupler-device and 65 (46.1%) performed by a hand-sewn venous anastomosis. Our analysis revealed that ischemia time and operation time were significantly shorter with the use of vaenous coupler device (P < 0.001; P < 0.001). No statistically significant differences were observed in postoperative complications. CONCLUSIONS: Venous coupler-assisted anastomosis in DIEP flap breast reconstruction does not increase postoperative complication rates and offers significant time reduction in both ischemia time and overall operative time. Given its reliability and efficiency, the microvascular coupler can safely be incorporated into DIEP flap breast reconstruction.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Everter-Assisted Arterial Coupling in Abdominal-Based Breast Reconstruction: A Preclinical Study and Retrospective Feasibility Case Series.Cancers · 2026
- Prophylactic Superdrained Deep Inferior Epigastric Perforator Flap: Systematic Review of Survival and Morbidity.Plastic and reconstructive surgery. Global open · 2026
- Case Report: Venous crossover bypass to the contralateral internal mammary vein to restore venous outflow in revision surgery in autologous free flap breast reconstruction.Frontiers in surgery · 2026
- Chemotherapy and microsurgical-related vascular complications in DIEP flap breast reconstruction: A retrospective study.Journal of plastic, reconstructive & aesthetic surgery : JPRAS · 2026
- Determinants and clinical impact of ischemia time in microsurgical breast reconstruction: A multicenter registry analysis of 4209 flaps.Journal of plastic, reconstructive & aesthetic surgery : JPRAS · 2026
- Intraoperative Venous Congestion in DIEP Flap Reconstruction: A Pooled Analysis Demonstrating the Limited Predictive Value of Patient-Level Risk Factors.Plastic surgery (Oakville, Ont.) · 2026