Plastic and reconstructive surgery. Global open

Coupler-assisted Versus Hand-sewn Venous Anastomosis in Deep Inferior Epigastric Perforator Flap Breast Reconstruction: A Single-institution Study.

Marlene Schelletter, Edward T C Dong, Salvatore Giordano, Gauthier Zinner, Carlo M Oranges

From the Department of Plastic, Reconstructive and Aesthetic Surgery, Geneva University Hospitals, Geneva University, Geneva, Switzerland. · Department of Plastic and General Surgery, Turku University Hospital and The University of Turku, Turku, Finland.

Observational · n=114

Key points

From the paper's conclusion
  • Venous coupler-assisted anastomosis in DIEP flap breast reconstruction does not increase postoperative complication rates and offers significant time reduction in both ischemia time and overall operative time. Given its reliability and efficiency, the microvascular coupler can safely be incorporated into DIEP flap breast reconstruction.

Abstract

BACKGROUND: Venous anastomosis remains a critical step in achieving successful free flap transfer. The venous coupler device has gained popularity due to its technically less demanding and time-efficient application. Although several retrospective and multicenter studies have evaluated coupler-assisted venous anastomosis in deep inferior epigastric perforator (DIEP) flap breast reconstruction, evidence remains heterogeneous. This study aims to compare mechanically performed versus hand-sewn venous anastomosis in DIEP flap breast reconstruction. METHODS: We retrospectively included patients who underwent unilateral or bilateral DIEP flap breast reconstruction following oncologic mastectomy between January 2018 and June 2024. We divided the patient cohort into 2 groups: coupler-assisted group and hand-sewn group. The primary outcome was the free flap ischemia time, and secondary outcomes included postoperative donor- and recipient-site complications. RESULTS: A total of 114 patients were included in this study, encompassing 141 DIEP flap breast reconstructions. This corresponds to 76 (53.9%) DIEP flap breast reconstructions performed using a venous coupler-device and 65 (46.1%) performed by a hand-sewn venous anastomosis. Our analysis revealed that ischemia time and operation time were significantly shorter with the use of vaenous coupler device (P < 0.001; P < 0.001). No statistically significant differences were observed in postoperative complications. CONCLUSIONS: Venous coupler-assisted anastomosis in DIEP flap breast reconstruction does not increase postoperative complication rates and offers significant time reduction in both ischemia time and overall operative time. Given its reliability and efficiency, the microvascular coupler can safely be incorporated into DIEP flap breast reconstruction.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers