Immunohistochemistry Assay Based on Ready-To-Use Antibodies and Vendor-Recommended Protocol Settings Often Perform Suboptimally.
Dordi Lea, Ivar Skaland
Department of Pathology, Stavanger University Hospital, Stavanger, Norway.
Key points
From the paper's conclusion- This study compares the performance of RTU antibodies from 2 major suppliers, Agilent (Dako Omnis platform) and Roche (BenchMark Ultra Plus system) in a Norwegian hospital setting.
Abstract
The use of ready-to-use (RTU) antibodies in pathology laboratories has increased due to regulatory changes and the need for standardized, efficient diagnostic workflows. This study compares the performance of RTU antibodies from 2 major suppliers, Agilent (Dako Omnis platform) and Roche (BenchMark Ultra Plus system) in a Norwegian hospital setting. A total of 125 RTU antibodies were evaluated using vendor-recommended protocol settings (VRPS) and scored according to NordiQC standards. Results showed that 58 out of 62 antibodies on the Dako Omnis platform were rated as "optimal" or "good," compared with 37 out of 63 on the BenchMark Ultra Plus. Notably, 26 (41.3%) of Roche antibodies were rated "borderline" or "poor." Our study shows that several RTU antibodies perform suboptimally with VRPS. This highlights the importance of thorough validation and verification of RTU antibodies before diagnostic use. The findings underscore the need for reliable protocols from manufacturers and encourage interlaboratory collaboration to improve diagnostic consistency and quality assurance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Inadequate antibody validation places substantial numbers of animal and human tissue samples at risk of waste.PLoS biology · 2026
- A multi-stakeholder Delphi consensus study proposes actionable solutions to address antibody validation failuresbioRxiv · 2026
- Actionable solutions to address antibody validation failures.PLoS biology · 2026
- Large-scale quantitative assessment of tissue preparation and staining conditions for robust multiplexed imaging of FFPE tissue samples.Nature methods · 2026
- B-050 Implementation and Performance Evaluation of Automated Autoverification for Tumor Marker Results in a High-Complexity Oncology LaboratoryClinical Chemistry · 2026
- A practical approach to assay imprecision evaluation for clinical laboratory professionals: from concept to application.Clinical chemistry and laboratory medicine · 2026