Screening Utility of Ambient Pressure Tympanometry for the Detection of Radiologic Correlates of Subjective Pulsatile Tinnitus.
Christian Bernard, Cyrus Khorassani, Monica Amarante, Greta Stamper, Joseph Breen, Mallory Raymond
Department of Otolaryngology-Head and Neck Surgery, Mayo Clinic Florida, Jacksonville, FL. · Department of Otolaryngology-Head and Neck Surgery, Geisinger Medical Center, Danville, PA.
Key points
From the paper's conclusion- With a low sensitivity and specificity, APT may not be a reliable screening tool for the detection of a radiologic correlate of subjective PT. Clinicians should continue to pursue radiologic evaluation of PT despite a negative APT and counsel patients on the limits of imaging and the potential need for multiple modalities for the detection of subjective PT sources.
Abstract
OBJECTIVE: To determine the sensitivity and specificity of ambient pressure tympanometry (APT) for the detection of a radiologic correlate of subjective pulsatile tinnitus (PT). STUDY DESIGN: Retrospective review. SETTING: Tertiary care clinic. PATIENTS: 107 adults (147 ears) with PT who underwent APT between 2021 and 2025. INTERVENTIONS: Blinded audiologists classified APT tracings as pulse-synchronous or not. MAIN OUTCOME MEASURES: Sensitivity and specificity of APT using any radiologic diagnosis or surgeon-defined diagnosis as 2 separate gold standards. RESULTS: Of 137 (93.2%) ears that underwent imaging, 63 (46%) had a pulse-synchronous APT pattern. Fifty-one (37.2%) had a radiologic correlate, and 65 (44.2%) were given a surgeon diagnosis. Respectively, APT sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were 51%, 57%, 41.3%, and 66.2% for a radiologic correlate and were 43.1%, 54.9%, 43.1%, and 54.9% for a surgeon diagnosis. In a subgroup of 86 patients (116 ears) with a chief complaint of PT, APT sensitivity, specificity, PPV, and NPV for a radiologic correlate were 56.9%, 54.2%, 46%, and 55.2%, and for a surgeon diagnosis were 43.6%, 54.1%, 46.2%, and 51.6%. CONCLUSION: With a low sensitivity and specificity, APT may not be a reliable screening tool for the detection of a radiologic correlate of subjective PT. Clinicians should continue to pursue radiologic evaluation of PT despite a negative APT and counsel patients on the limits of imaging and the potential need for multiple modalities for the detection of subjective PT sources.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Paired-ear tympanometric pressure patterns and hearing recovery in unilateral sudden sensorineural hearing loss: a retrospective cohort study.Frontiers in neurology · 2026
- Accuracy of tympanometry cutoff points in children from Central-Western Brazil.CoDAS · 2026
- Hemodynamic Changes Following Acupuncture and Moxibustion in Patients with Subjective Tinnitus: An Acceleration Photoplethysmography and Pulsed-Wave Doppler Ultrasound Study.Audiology research · 2026
- Eustachian Tube Dysfunction and Tinnitus: A Rapid Review of the Potential Complementary Role of Acoustic Immittance.The journal of international advanced otology · 2026
- Clinical Characteristics of Patulous Eustachian Tube and the Diagnostic Efficiency of Compliance-Over-Time Testing.Journal of otolaryngology - head & neck surgery = Le Journal d'oto-rhino-laryngologie et de chirurgie cervico-faciale · 2026
- Sensitivity, Specificity, and Reproducibility of 2 kHz cVEMP and 4 kHz oVEMP Tone Burst in Superior Semicircular Canal Dehiscence Syndrome.Audiology & neuro-otology · 2026