Intraoperative Goal-Directed Perfusion Improves Outcomes in Left Ventricular Assist Device Explant Heart Transplantation.
Chen Chia Wang, Mark Petrovic, Awab Ahmad, Walter Navid, Christian Eidson, Kevin McGann, John Trahanas, Swaroop Bommareddi,
From the Department of Cardiac Surgery, Vanderbilt University Medical Center, Nashville, Tennessee. · Division of Cardiology, Department of Medicine, Vanderbilt University Medical Center, Nashville, Tennessee.
Key points
From the paper's conclusion- These findings suggest that cumulative oxygen extraction during CPB reflects intraoperative metabolic stress and may represent a physiologically integrated perfusion target in LVAD-explant heart transplantation.
Abstract
Left ventricular assist device (LVAD) explant heart transplantation represents a metabolically vulnerable population with an increased risk for renal failure and mortality. Oxygen extraction ratio (O2ER), which integrates oxygen delivery and tissue oxygen demand, may provide a physiologic marker of cumulative metabolic stress during cardiopulmonary bypass (CPB). Adult LVAD-explant heart transplant recipients at a single center from October 2021 to June 2025 were analyzed using continuous perfusion data captured during CPB. Oxygen extraction ratio was calculated continuously, and cumulative oxygen extraction burden was quantified as the area above an O2ER threshold of 0.20. Patients were stratified by median O2ER burden. Among 110 patients, a higher intraoperative O2ER burden was associated with increased postoperative renal replacement therapy (odds ratio [OR], 4.16; 95% confidence interval [CI], 1.35-12.83) and increased 2-year mortality (hazard ratio [HR], 7.61; 95% CI, 1.49-38.73) after inverse probability weighting adjustment. A higher O2ER burden was also associated with a lower immediate postoperative cardiac index and increased vasoactive inotrope requirements. Donor hypertension, recipient diabetes, static storage modality, and a lower intraoperative oxygen delivery index were associated with an increased O2ER burden. These findings suggest that cumulative oxygen extraction during CPB reflects intraoperative metabolic stress and may represent a physiologically integrated perfusion target in LVAD-explant heart transplantation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Impact of a durable left ventricular assist device on inflammation and cardiac remodelling in subjects with advanced heart failure.Open heart · 2026
- Insulin Resistance Compromises the Pentose Phosphate Pathway and Impairs Left Ventricular Assist Device–Mediated Myocardial Recovery in Obese Patients With Heart FailureCirculation · 2026
- Primary graft dysfunction after LVAD bridge-to-transplant: a systematic review and meta-analysisEuropean Heart Journal · 2026
- Machine Perfusion in Liver Transplantation: A Systematic Review and Meta-Analysis Comparing Outcomes with Conventional Static Cold Storage.Journal of clinical medicine · 2026
- Pre-implant right heart catheterization and liver biomarkers in left ventricular assist device candidatesEuropean Heart Journal · 2026
- Intravascular hemolysis and clinical outcomes in continuous-flow LVAD patients: A single-center retrospective analysis.The International journal of artificial organs · 2026