Long-Term Outcomes After Cochlear Implantation in Incomplete Partition Type II: A Single-Center Retrospective Cohort Study.
Callum Findlay, Emelyne Arthur, Rachel Titcombe, Kate Hough, Mary Grasmeder, Tracey A Newman
Faculty of Medicine, University of Southampton. · Auditory Implant Service, University of Southampton, Southampton, UK.
Key points
From the paper's conclusion- In this cohort, cochlear implantation in IP-II was associated with frequent CSF leaks and variable hearing outcomes, with performance often continuing to improve up to around 3 years after implantation. Rating scales (CAP, SIR) and BKB testing in quiet did not reliably identify poorer performers, whereas adaptive BKB testing in noise did. Preoperative counseling should address the risk of CSF leaks and the extended time to peak performance. Routine outcome assessment should include speech-perception testing in noise once at an appropriate age.
Abstract
OBJECTIVE: To characterize long-term audiological outcomes after cochlear implantation (CI) in individuals with incomplete partition type II (IP-II). STUDY DESIGN: Retrospective cohort study. SETTING: Single UK cochlear implant center. PATIENTS: Thirty-two individuals (47 implanted ears); 22 (69%) female, 12 (38%) adults at implantation with a mean follow-up of 11 years (SD: 7.53). INTERVENTION: Cochlear implantation in ears diagnosed with IP-II. MAIN OUTCOME MEASURES: Anatomic features on computed tomography (CT) and magnetic resonance imaging (MRI); surgical complications including cerebrospinal fluid (CSF) events; extracochlear electrode placement; audiometric outcomes comprising Categories of Auditory Performance (CAP), Speech Intelligibility Rating (SIR), and Bamford-Kowal-Bench (BKB) sentence tests in quiet and adaptive noise; electrode deactivations; impedance measurements; and device usage. RESULTS: All ears underwent presurgical CT; 27 (58%) also had MRI. The complete Mondini triad was present in 31 ears (66%). CSF ooze occurred in 14 cases (30%) and CSF gusher in 9 (19%). At 3 years post-implantation, median CAP and SIR scores were 6 (range: 4 to 7) and 4 (range: 1 to 5), respectively. Median BKB sentence score in quiet was 91% correct [interquartile range (IQR): 1.5], and 5.85 dB SNR (IQR: 7.65) in adaptive noise. CONCLUSIONS: In this cohort, cochlear implantation in IP-II was associated with frequent CSF leaks and variable hearing outcomes, with performance often continuing to improve up to around 3 years after implantation. Rating scales (CAP, SIR) and BKB testing in quiet did not reliably identify poorer performers, whereas adaptive BKB testing in noise did. Preoperative counseling should address the risk of CSF leaks and the extended time to peak performance. Routine outcome assessment should include speech-perception testing in noise once at an appropriate age.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cochlear implantation in children with cerebral palsy: a retrospective cohort study of auditory and speech outcomes.Acta oto-laryngologica · 2026
- Cochlear implants in adults: outcomes in prolonged auditory deprivation.Cochlear implants international · 2026
- Three decades of cochlear implant failure and multiple reimplantation: a retrospective cohort study.Frontiers in surgery · 2026
- Relationship Between Age, Auditory Performance, and Quality of Life in Middle-Aged and Older Cochlear Implant Users.Journal of the American Academy of Audiology · 2026
- Contralateral Hearing Status as a Determinant of Cochlear Implant Device Engagement and Rehabilitation Trajectory.Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery · 2026