Hearing Preservation as a Function of Angular Insertion Depth With Manual Versus Robotic-Assisted Insertion Techniques.
Carlos A Perez-Heydrich, Margaret T Dillon, Elena Quinonez Del Cid, Madison Elizabeth Broome, Margaret E Richter, Samantha P Scharf, Anne Morgan Selleck, Matthew M Dedmon,
Department of Otolaryngology/Head and Neck Surgery.
Key points
From the paper's conclusion- Robotic-assisted electrode array insertion may support better early hearing preservation compared with manual insertions, particularly for patients with electrode arrays placed at deeper AIDs.
Abstract
OBJECTIVE: This study reviewed the early shifts in low-frequency hearing for cochlear implant (CI) hearing preservation candidates who underwent cochlear implantation using either manual or robotic-assisted insertion of the electrode array and evaluated possible contributing factors such as angular insertion depth (AID), preoperative hearing, and age. PATIENTS: Adult CI hearing preservation candidates (≥18 yr, ≤70 dB HL at 250 Hz) who underwent cochlear implantation with a straight electrode array through a manual or robotic-assisted insertion. MAIN OUTCOME MEASURES: A low-frequency pure tone average (125, 250, and 500 Hz) was calculated from the unaided thresholds obtained preoperatively and within the initial weeks following surgery. Queried data included impedance values measured intraoperatively and at CI activation, and the AID of the most apical electrode contact. RESULTS: Of 120 cases (66 females), 92 underwent manual insertion (median age = 69.0 yrs, interquartile range = 63.5 to 79.0) and 28 underwent robotic-assisted insertion (median age = 67.0 yrs, interquartile range = 60.9 to 76.3). Patients received either a 23, 24, 26, 28, or 31.5 mm electrode array. Significantly less low-frequency pure tone average shift was observed for robotic-assisted insertions (P = 0.028), shallower AIDs (P = 0.010), and younger patients (P = 0.001). There was a significant interaction between insertion group and AID (P = 0.010), with robotic-assisted insertion demonstrating better hearing preservation at AIDs exceeding 490°. Impedance values did not differ significantly between insertion groups intraoperatively or at CI activation. CONCLUSIONS: Robotic-assisted electrode array insertion may support better early hearing preservation compared with manual insertions, particularly for patients with electrode arrays placed at deeper AIDs. LEVEL OF EVIDENCE: Level IV; retrospective cohort study.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of Cochlear Implant Hearing Outcomes Following Manual and Robotic Electrode Insertion.Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery · 2026
- Comparison of robotic-assisted and manual cochlear implant electrode array insertions considering cochlear geometric factors.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2026
- Robotic‐Assisted Electrode Array Insertion Improves Stability of Acoustic Hearing ThresholdsThe Laryngoscope · 2026
- Early Clinical Experience With Robot-Assisted Electrode Insertion in Cochlear Implantation Using the Otoarm-Otodrive System.Journal of otolaryngology - head & neck surgery = Le Journal d'oto-rhino-laryngologie et de chirurgie cervico-faciale · 2026
- Impact of Robotic-Assisted Electrode Array Insertion on Neural Health and Hearing Outcomes in Cochlear Implant Recipients.Audiology & neuro-otology · 2026
- Hearing preservation outcomes with motorized cochlear implant electrode insertion: matched-cohort observationsFrontiers in Surgery · 2025