Comparison of Cochlear Implant Hearing Outcomes Following Manual and Robotic Electrode Insertion.
Ilana Yellin, Nathan M Jacob, Michael D Seidman, ArielMae Brownlee
Department of Otolaryngology-Head and Neck Surgery, AdventHealth Celebration, Celebration, Florida, USA. · Department of Otolaryngology-Head and Neck Surgery, University of Central Florida College of Medicine, Orlando, Florida, USA.
Key points
From the paper's conclusion- There is no significant difference in initial LFHP between robotic-assisted and manual CI in this study group, though robotic-assisted insertion may still offer benefit for preservation of residual hearing over time. Further studies with longer follow-up are needed to fully evaluate the impact of robotic-assisted insertion on hearing preservation.
Abstract
OBJECTIVE: The purpose of this study is to compare initial low frequency hearing preservation (LFHP) in patients undergoing robotic-assisted cochlear implantation (CI) to those undergoing manual CI. STUDY DESIGN: Retrospective review. SETTING: Tertiary referral center. METHODS: Adult CI patients with low-frequency residual hearing, defined as a preoperative low-frequency pure tone average (LFPTA) at 250 and 500 Hz ≤80 dB HL, were included in this study. Patients underwent either robotic-assisted or manual CI. All implants utilized lateral wall electrodes. The primary outcomes were the change in LFPTA (ΔLFPTA) and the presence of LFHP, defined as ΔLFPTA ≤ 30 dB HL, following robotic-assisted or manual CI. RESULTS: 35 robotic-assisted and 27 manual cases met the inclusion criteria for comparison of initial LFHP. The mean preoperative LFPTA was 56.14 and 62.04 dB HL (P = .11) while the mean postoperative LFPTA was 88.86 and 91.02 dB HL for robotic-assisted and manual insertion, respectively (P = .63). The ΔLFPTA was not significantly different between the robotic-assisted and manual insertion groups (32.17 dB HL robotic-assisted vs 28.98 dB HL manual, P = .82). LFHP was similar between groups (57.10% robotic-assisted vs 51.90% manual, P = .68). CONCLUSION: There is no significant difference in initial LFHP between robotic-assisted and manual CI in this study group, though robotic-assisted insertion may still offer benefit for preservation of residual hearing over time. Further studies with longer follow-up are needed to fully evaluate the impact of robotic-assisted insertion on hearing preservation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Hearing Preservation as a Function of Angular Insertion Depth With Manual Versus Robotic-Assisted Insertion Techniques.Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2026
- Robotic‐Assisted Electrode Array Insertion Improves Stability of Acoustic Hearing ThresholdsThe Laryngoscope · 2026
- Comparison of robotic-assisted and manual cochlear implant electrode array insertions considering cochlear geometric factors.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2026
- Impact of Robotic-Assisted Electrode Array Insertion on Neural Health and Hearing Outcomes in Cochlear Implant Recipients.Audiology & neuro-otology · 2026
- Hearing preservation outcomes with motorized cochlear implant electrode insertion: matched-cohort observationsFrontiers in Surgery · 2025
- Early Clinical Experience With Robot-Assisted Electrode Insertion in Cochlear Implantation Using the Otoarm-Otodrive System.Journal of otolaryngology - head & neck surgery = Le Journal d'oto-rhino-laryngologie et de chirurgie cervico-faciale · 2026