Real-Time Intracochlear Distance Sensing and Navigation Using a Dual Fiber Optical Coherence Tomography System.
Pawina Jiramongkolchai, Senyue Hao, Rosana Alfaro, Meitong Nie, Aaron J Adkins, Abigail Matt, Ratul Paul, Jay F Piccirillo,
Department of Otolaryngology - Head and Neck Surgery, Washington University in St. Louis, St. Louis, MO. · Department of Electrical and Systems Engineering, Washington University in St. Louis, St. Louis, MO.
Key points
From the paper's conclusion- A dual fiber-based SDM-OCT system can be used to provide real-time spatial navigation and distance calculation to the cochlear walls.
Abstract
HYPOTHESIS: A dual fiber-based optical coherence tomography (OCT) system can be used for real-time intracochlear navigation and distance computation in the human cochlea. BACKGROUND: OCT is a contrast- and radiation-free modality that provides real-time 2- and 3-dimensional imaging of tissue microanatomy at higher resolutions than those of conventional MRI or CT. Because the fundamental working principle of OCT is to measure the time delay of backscattered near-infrared light using low-coherence interferometry, OCT functions as an intrinsic light-based distance sensor. METHODS: A single- and dual-fiber attached to a custom-built 1310 nm swept-source (SS) OCT system was validated in cochlear phantoms and tested in a human cadaveric cochlea to compute the distance of the fibers from the lateral and medial walls. Curvature and distance of the fibers to the lateral and medial walls of the scala tympani were obtained during insertion and pull-back of the fibers as accessed through a round window approach. RESULTS: Our fiber-based SS-OCT system can detect a maximum distance of 7.10 mm with an axial resolution of 10 µm at an acquisition speed of 8 µs. Using space-division multiplexing (SDM) for our dual fiber, we were able to simultaneously obtain distance measurements from 2 spatially separated locations without the need for mechanical rotation. Furthermore, our custom user interface provided an immediate 3-color-coded warning system, which facilitated real-time microadjustments of fiber trajectory to avoid intracochlear trauma. CONCLUSION: A dual fiber-based SDM-OCT system can be used to provide real-time spatial navigation and distance calculation to the cochlear walls.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- High-Resolution Intraoperative Guide for Cochlear Implant Surgery Using Optical Coherence Tomography.Audiology & neuro-otology · 2026
- Custom optical coherence tomography/confocal scanning laser microscope system for rapid measurement of cell size.Biomedical optics express · 2026
- Neurointerventional optical coherence tomography using a piezo-driven microprobe.Biomedical optics express · 2026
- Ultra-thin, forward-viewing OCT endoscope using a rotating angle-cleaved fiber.Biomedical optics express · 2026
- Real-time en-face optical coherence tomography using a 9 GHz photodetected signal.Optics express · 2026
- Measurement of fluid diffusion coefficient based on bidirectional scanning in optical coherence tomography.Optics letters · 2026