From Compliance to Collaboration to Culture: A Prospective Evaluation of the HIPESAC Timeout and Patient Safety Advocate Platform.
James F Schlund, Ashley Davis, Linda Esparza, Sadie M Voigtlander
Department of Radiology, Briner Breast Care Center, Tahoe Forest Health System, Truckee, CA. · Office of Patient Safety, Tahoe Forest Health System, Truckee, CA.
Key points
From the paper's conclusion- The platform was feasible, well accepted, and surfaced latent procedural threats in this single-center evaluation. By requiring the proceduralist to present to the team and, at higher risk, inverting the order of voice, it may operationalize authority-gradient inversion as an intrinsic feature. Multi-site controlled evaluation is warranted.
Abstract
BACKGROUND: The Universal Protocol has standardized pre-procedural verification since 2004, yet procedural sentinel events persist; 127 wrong-surgery events were reported nationally in 2024. Compliance-based checklists may be insufficient for the human-factors environment of complex procedural care. METHODS: In a prospective 3-phase quality improvement evaluation at a rural health system, we tested an enhanced timeout (HIPESAC) in which the proceduralist presents and justifies each verification element to the full team, any member empowered to question, correct, or halt the procedure. For high-risk cases, an expanded Patient Safety Advocate (PSA) protocol adds voicing of concerns from least to most senior, with a designated patient advocate issuing consent to proceed. Phase 1 piloted 4 PSA-activated procedures; Phase 2 audited 20 with surveys; and Phase 3 evaluated the standard timeout across 22 procedures. RESULTS: The platform identified latent threats before initiation: material readiness events in 8 of 20 high-risk procedures (40%; one critical absent item, 7 proactive adjustments) and 9 process deficiencies across 22 standard procedures. The timeout added a median of 54 seconds. Surveys indicated high acceptance among respondents, with unanimous endorsement of speaking-up empowerment. In 2 cases-one per tier-a non-proceduralist surfaced information that altered the procedure. CONCLUSIONS: The platform was feasible, well accepted, and surfaced latent procedural threats in this single-center evaluation. By requiring the proceduralist to present to the team and, at higher risk, inverting the order of voice, it may operationalize authority-gradient inversion as an intrinsic feature. Multi-site controlled evaluation is warranted.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Mind the Gap: Reported Versus Observed Surgical Safety Checklist Time‐Out Adherence in the Hybrid Operating RoomWorld Journal of Surgery · 2026
- Visual alert integration with a time out monitor improves utilisation of an AI safety authentication system in ophthalmic surgery: a 1-year before-after study.BMJ open quality · 2026
- Sim-SEA: Integrating Significant Event Audit and In Situ Simulation to Support Patient Safety Learning and Organizational Change-A Prospective Single-Center Pilot Study in Pediatric Emergency Care.Healthcare (Basel, Switzerland) · 2026
- Non-clinical interventions to improve patient safety in the perioperative care process: An umbrella review.Journal of healthcare quality research · 2026
- Feeling better informed and more confident to speak up in the operating room: team effects of a structured intraoperative briefing intervention - a before-after study.BMJ open quality · 2026
- Translational simulation in anaesthesia: a systematic review of applications, processes, outcomes, and implementation factors.British journal of anaesthesia · 2026