BMJ open quality

Visual alert integration with a time out monitor improves utilisation of an AI safety authentication system in ophthalmic surgery: a 1-year before-after study.

Hitoshi Tabuchi, Naofumi Ishitobi, Mao Tanabe, Yuta Nakaniida, Masahiro Akada

Department of Ophthalmology, Tsukazaki Hospital, Himeji, Hyogo, Japan h.tabuchi@tsukazaki-eye.net. · Department of Ophthalmology, Tsukazaki Hospital, Himeji, Hyogo, Japan.

Observational

Key points

From the paper's conclusion
  • A small, human-factors-informed User Interface (UI) change substantially improved day-to-day utilisation of an established AI safety system without added devices or steps. Because the approach modifies a common time out display, it is language-independent and low-cost, and may be transferable to other verification tasks (eg, implant or blood product checks).

Abstract

BACKGROUND: AI-enabled verification can prevent wrong-patient and wrong-site events, but benefit depends on consistent use. We previously reported the real-world performance of an AI safety authentication system in ophthalmology, observing that most errors occurred when the system was not used. OBJECTIVE: To test whether integrating a conspicuous visual alert into the operating-room time out monitor increases routine utilisation of the existing AI system. METHODS: A single-centre before–after study spanning 1 year preimplementation (August 2023–July 2024) and 1 year postimplementation (September 2024–August 2025); the deployment month was excluded. The software-only intervention added a dynamic border to the time out monitor: flashing red until all required authentications were complete, then solid green. Primary outcome was non-utilisation (encounters with ≥1 required authentication not performed). RESULTS: Across 18 669 preimplementation and 18 910 postimplementation encounters, non-utilisation fell from 0.52% (98/18 669) to 0.17% (33/18 910)—a 66.8% relative reduction (Fisher’s exact p<0.001). Facial recognition and laterality verification decreased (both p<0.001), while intraocular lens verification decreased without statistical significance (p=0.14). CONCLUSIONS: A small, human-factors-informed User Interface (UI) change substantially improved day-to-day utilisation of an established AI safety system without added devices or steps. Because the approach modifies a common time out display, it is language-independent and low-cost, and may be transferable to other verification tasks (eg, implant or blood product checks).

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Visual alert integration with a time out monitor improves utilisation of an AI safety authentication system in ophthalmic surgery: a 1-year before-after study — Science Skim