Journal of cataract and refractive surgery

Visual and Patient-Reported Outcomes of a Bilaterally Implanted Enhanced Monofocal IOL: A Prospective, Multicenter Study.

I Paul Singh, Michael Patterson, Zaina Al-Mohtaseb, Brandon D Ayres, George Lau, Farrell Tyson, Ravi Patel, Ehsan Sadri,

Eye Centers of Racine & Kenosha, Racine, WI, USA. · Eye Centers of Tennessee, Crossville, TN, USA.

Observational

Key points

From the paper's conclusion
  • Bilateral implantation of enVista Aspire partial-depth-of-field enhanced monofocal IOL demonstrated very good uncorrected visual acuity at far and intermediate and can be a good option for patients who prioritize good distance and intermediate vision and a favorable dysphotopsia profile.

Abstract

PURPOSE: To evaluate the real-world visual and patient-reported outcomes of partial-depth-of-field enhanced monofocal IOL bilaterally implanted in cataract patients targeted for emmetropia. SETTING: 57 US clinical sites. DESIGN: Prospective, multicenter, single-arm study. METHODS: This study included 338 subjects (651 eyes) who desired cataract surgery and implantation of an enVista Aspire IOL to achieve bilateral emmetropia. RESULTS: The mean MRSE was -0.18 ± 0.37 D; 85% (551/648) of eyes were within ±0.50 D. The mean binocular UDVA and CDVA were 0.02±0.10 and -0.03±0.07 logMAR, respectively, with 96.5% (299/310) and 99.7% (309/310) of subjects achieving binocular UDVA and CDVA of 20/32 or better. Mean binocular UIVA was 0.20±0.15 logMAR, with 70.9% (219/309) of subjects achieving UIVA of 20/32 or better. Vision at far and intermediate distances without corrective devices was rated as pretty to perfectly well by 92.6% (286/309) of subjects, and 89.6% (277/309) of subjects were satisfied with their postoperative vision. The frequency and bothersomeness of visual symptoms were low (90% or higher proportion of subjects reported visual symptoms occurring "never" to "sometimes"), and almost 90% or higher reported being "not at all" or "only a little" bothered by them. With NAVQ, 52.1% to 71.8% of subjects reported "no or a little difficulty" in doing intermediate to near vision tasks. CONCLUSION: Bilateral implantation of enVista Aspire partial-depth-of-field enhanced monofocal IOL demonstrated very good uncorrected visual acuity at far and intermediate and can be a good option for patients who prioritize good distance and intermediate vision and a favorable dysphotopsia profile.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers