Biometry-Driven Selection of IOL Power Calculation Formulas Using the ESCRS IOL Calculator.
Youngsub Eom, Miri Na, Jinhwan Park, Youngbin Song, Dong Hyun Kim, Cheolmin Yun, Jong Suk Song, David L Cooke,
YES Eye Clinic, Seoul, Republic of Korea. · Department of Ophthalmology, Korea University College of Medicine, Seoul, Republic of Korea.
Key points
From the paper's conclusion- Selecting IOL power calculation formulas according to biometric subgroups defined by K, ACD, and AL improves refractive prediction accuracy compared with individual formulas. A biometry-driven formula selection strategy using the ESCRS IOL Calculator may provide a clinically useful approach for optimizing refractive outcomes after cataract surgery.
Abstract
PURPOSE: To evaluate the accuracy of a biometric subgroup-based intraocular lens (IOL) power calculation formula selection strategy using the ESCRS IOL Calculator. SETTING: Kim's Eye Hospital and Korea University Ansan Hospital, Republic of Korea. DESIGN: Retrospective comparative study. METHODS: A total of 626 eyes that underwent uncomplicated cataract surgery with in-the-bag IOL implantation were included. Eyes were divided into a derivation dataset (351 eyes) and an independent external-validation dataset (275 eyes). Biometric subgroups were defined based on combinations of keratometry (K), anterior chamber depth (ACD), and axial length (AL), resulting in 640 subgroups. For each subgroup, the formula with the lowest mean absolute error (MAE) was selected using the derivation dataset. For subgroups not represented in the derivation dataset, formulas were assigned using a median-based approach. Prediction accuracy in the validation dataset was compared between the subgroup-based method and seven individual formulas. RESULTS: The subgroup-based method demonstrated the lowest MAE (0.24 ± 0.19 D) and MedAE (0.19 D) among all methods (p<0.001). The proportion of eyes within ±0.50 D was higher with the subgroup-based method (89.1%) compared with individual formulas (approximately 80%; p<0.001). The subgroup-based method also showed the highest IOL Formula Performance Index (0.609) compared with individual formulas (0.377-0.560). CONCLUSIONS: Selecting IOL power calculation formulas according to biometric subgroups defined by K, ACD, and AL improves refractive prediction accuracy compared with individual formulas. A biometry-driven formula selection strategy using the ESCRS IOL Calculator may provide a clinically useful approach for optimizing refractive outcomes after cataract surgery.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of the Accuracy of the Web-Based ESCRS IOL Power Calculator Formulas.Seminars in ophthalmology · 2026
- A retrospective multi-center validation study of tomography-based formulas for phakic intraocular lens sizing.Journal of cataract and refractive surgery · 2026
- Stratified Analysis of IOL Constant Optimization and Refractive Prediction Accuracy According to Ocular Biometric Parameters: Comparison with Overall Optimization.Ophthalmology and therapy · 2026
- Efficacy of Total Keratometric Power and Total Corneal Power on the Accuracy of 8 Modern Intraocular Lens Formulas in Highly Myopic Eyes.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- Best formulas for highly myopic patients (axial length ≥26 mm) receiving cataract surgery.Current opinion in ophthalmology · 2026
- Inter-Formula Variability in IOL Power Planning in Short and Long Eyes: A Retrospective Paired Comparison of Seven ESCRS-Hosted Formulas and the Ladas Super Formula 2.0.Clinical ophthalmology (Auckland, N.Z.) · 2026