Safety and Performance of a New Cohesive Ophthalmic Viscosurgical Device - a Multicenter, Partially Comparative Randomized Study.
Carmen Vogt, Maria Xeroudaki, Alexander Fridberg, Björn Johansson
Bohus Biotech, Strömstad, Sweden. · Clinical Department of Ophthalmology, Region Östergötland, Linköping, Sweden.
Key points
From the paper's conclusion- This study demonstrates the safety of Minivisc® Plus in terms of IOP spikes, postoperative ocular inflammation, ECD loss, with clinical performance comparable to that of Healon GV® PRO.
Abstract
PURPOSE: To confirm the clinical safety and overall performance of Minivisc® Plus, a cohesive ophthalmic viscosurgical device (OVD). SETTING: Multicenter study conducted at 6 sites in Sweden and Belgium. DESIGN: Prospective, randomized, partially comparative, multicenter post market study. METHODS: Subjects requiring anterior segment ophthalmic surgery were eligible for inclusion. The study consisted of two phases. In Phase A (90-day follow-up), a randomized comparison was conducted between Minivisc® Plus and Healon GV® Pro. In Phase B, eyes were treated with Minivisc® Plus and followed for 30 days. Primary endpoint was incidence of intraocular pressure (IOP) ≥30 mmHg at 7 days following operation. Secondary endpoints included postoperative inflammation, corneal endothelial cell density (ECD), surgeon-reported device performance, and the incidence of adverse events (AEs) and device deficiencies (DDs). RESULTS: In total, 163 eyes were included in the study: 54 eyes in Phase A (25 eyes treated with Minivisc® Plus and 29 eyes treated with Healon GV® Pro) and 109 eyes in Phase B. All surgical procedures were phacoemulsification cataract surgeries, apart from two cases (both in Phase B), which were glaucoma surgeries. Two eyes (1.5%) treated with Minivisc® Plus exhibited intraocular pressure (IOP) ≥30 mmHg at postoperative day 7. Inflammation grading, ECD loss, and the incidence of AEs were comparable between the study substances throughout the 90-day follow-up period. Surgeon-reported assessments indicated comparable device performance between the two OVDs. CONCLUSIONS: This study demonstrates the safety of Minivisc® Plus in terms of IOP spikes, postoperative ocular inflammation, ECD loss, with clinical performance comparable to that of Healon GV® PRO.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Safety and Efficacy of Eyevisc™ 2.4% Ophthalmic Viscosurgical Device in Cataract Surgery.Cureus · 2026
- Comparison of Safety and Efficacy of Two Dispersive Hyaluronate OVDs Used in Cataract Surgery.Ceska a slovenska oftalmologie : casopis Ceske oftalmologicke spolecnosti a Slovenske oftalmologicke spolecnosti · 2026
- Visual and Patient-Reported Outcomes of a Bilaterally Implanted Enhanced Monofocal IOL: A Prospective, Multicenter Study.Journal of cataract and refractive surgery · 2026
- ELIOS Excimer Laser Trabeculostomy with Phacoemulsification in Primary Open-Angle Glaucoma: 24-Month Outcomes of Pivotal Trial.Ophthalmology. Glaucoma · 2026
- Safety of Bio-Interventional Uveoscleral Outflow Enhancement: Twelve-Month Post-Operative Results from 395 Eyes in the CREST StudymedRxiv · 2026
- 12-Month Visual and Clinical Outcomes After Implantation of a Monofocal Aspheric Hydrophobic Acrylic IOL: A Prospective Feasibility Study.Clinical ophthalmology (Auckland, N.Z.) · 2026