Impact of Scleral Lens Wear on Intraocular Pressure, Retinal Structure, and Choroidal Vascularity.
Rabia Eroğlu, Gamze Ozkan, Semra Akkaya Turhan
Department of Ophthalmology (R.E., G.O.), Marmara University School of Medicine, Istanbul, Türkiye; and Department of Ophthalmology (S.A.T.), Mehmet Ali Aydınlar University School of Medicine, Istanbul, Türkiye.
Key points
From the paper's conclusion- Four hours of SL wear was not associated with statistically significant changes in IOP, RNFL, GCC, SFCT, or CVI in habitual SL wearers with keratoconus.
Abstract
OBJECTIVES: To evaluate the effects of scleral lens (SL) wear on intraocular pressure (IOP), retinal parameters, and choroidal metrics in habitual SL wearers with keratoconus. METHODS: This cross-sectional study included 25 eyes of 25 habitual SL wearers with keratoconus and 25 eyes of 25 healthy controls. Measurements were obtained before SL wear and immediately after lens removal after 4 hr of wear. IOP, retinal nerve fiber layer (RNFL), ganglion cell complex (GCC), subfoveal choroidal thickness (SFCT), and choroidal vascularity index (CVI) were evaluated. RESULTS: Mean SL wear duration was 3.9±3.8 years. Mean IOP was 12.16±3.00 mm Hg before wear and 12.14±2.90 mm Hg after 4 hr, with a paired mean difference of 0.01 mm Hg (95% CI, -0.76 to 0.78; P=0.678). No statistically significant changes were observed in RNFL, GCC, SFCT, or CVI after 4 hr (P=0.929, 0.094, 0.098, and 0.424, respectively). CVI did not differ between groups before or after SL wear (P=0.114 and 0.358, respectively). CONCLUSIONS: Four hours of SL wear was not associated with statistically significant changes in IOP, RNFL, GCC, SFCT, or CVI in habitual SL wearers with keratoconus.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Changes in Visual Acuity and Dry Eye Parameters Following One Month of Scleral Lens Wear in Patients with Keratoconus: A Prospective Observational Study from Saudi Arabia.Healthcare (Basel, Switzerland) · 2026
- Clinical outcomes of scleral lenses in keratoconus: a systematic review and Meta-analysis.International journal of ophthalmology · 2026
- Long-term evaluation of anterior segment structures after implantable collamer lens V4c implantation.International ophthalmology · 2026
- The Effect of Limbal Fenestrations on Scleral Lens-Induced Central Corneal OedemaOphthalmic and Physiological Optics · 2026
- Agreement between Sirius Scheimpflug-Placido tomography and Anterion swept-source OCT in keratoconic eyes stratified by prior corneal cross-linking: a retrospective cross-sectional agreement study.International ophthalmology · 2026
- Differential Effects of EVO/EVO+ Implantable Collamer Lens on Anterior Chamber Angle Morphology: A Comparative Cohort Study.Photodiagnosis and photodynamic therapy · 2026