Key points
From the paper's conclusion- Patients requiring CIED interrogation experienced delays relative to other patients, with interrogation as the proximate step before disposition. Consults after hours took longer, and delays were independently associated with admission. These findings highlight an operational bottleneck in acute CIED management, and efforts to expedite device interrogation warrant further investigation.
Abstract
OBJECTIVES: Patients with cardiac implantable electronic devices (CIEDs), such as pacemakers and implantable cardioverter-defibrillators, frequently present to the emergency department (ED) with complaints potentially attributable to their devices. Device interrogation can characterize arrhythmias and guide management, but whether it represents a bottleneck to disposition has not been systematically studied. METHODS: Retrospective cohort study at two academic centers (2024-2026). Visits were identified via consultations. Control cohorts of patients with general cardiology and EP consultations with pacemakers were propensity score matched. Intervals were compared via Kruskal-Wallis tests. Logistic regression investigated associations between demographic factors, time intervals, and admission. RESULTS: We identified 677 visits from 479 unique patients involving CIED-related EP consultation. The median ED length of stay (LOS) was 24.3 hours (IQR 10.2-36.1), with 80.4% admitted. General cardiology and EP consults without interrogation demonstrated similar times to consultation (4.0 [IQR 1.8-11.1] and 3.0 [IQR 0.9-12.4], p=0.4 and p=0.1), but shorter from consult to disposition (13.3 hours [IQR 12.7-14.4] vs. 5.2 [IQR 4.5-5.9] and 6.8 [IQR 6.0-7.5], both p<0.001). Consults with interrogation after hours were prolonged (14.9 [IQR 7.1-20.5] vs 7.1 [IQR 5.4-11.1], p<0.001). In the logistic regression, longer consultations were associated with higher likelihood of admission (aOR 1.05, 95% CI 1.02-1.07 per hour). No other factors were significant. CONCLUSION: Patients requiring CIED interrogation experienced delays relative to other patients, with interrogation as the proximate step before disposition. Consults after hours took longer, and delays were independently associated with admission. These findings highlight an operational bottleneck in acute CIED management, and efforts to expedite device interrogation warrant further investigation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The impact of cardiac implantable electronic devices on delays to acute magnetic resonance imaging: a two-year service evaluationEuropean Heart Journal · 2026
- Immediate Ambulatory Electrocardiographic Monitoring in Syncope.The New England journal of medicine · 2026
- Diagnosing a cardiac cause for palpitations: Five-year service evaluation of a smartphone ambulatory ECG pathway for Emergency Department patients.medRxiv · 2026
- Long-term safety and efficacy of arrhythmia monitoring with an implantable cardiac monitor.International journal of cardiology · 2026
- Time-Dependent Diagnostic Yield and Therapeutic Impact of Implantable Loop Recorders, Brugada Syndrome as the Exception.Journal of cardiovascular electrophysiology · 2026
- ARTIFICIAL INTELLIGENCE AND REMOTE MONITORING OF CARDIAC DEVICES: A NARRATIVE REVIEW.Indian pacing and electrophysiology journal · 2026