Measurement of Femoral Neck Anteversion Angle in Children With Intoeing Gait by Using Femoral Plain Radiographs: A Retrospective Observational Study.
Meng-Yu Liu, Shu-Hsin Yao, Chen-Kun Liaw, Jou-Hua Wang, Chang-Hao Lin, Chun-Ho Chen
Department of Orthopaedics, Ditmanson Medical Foundation Chia-Yi Christian Hospital, Chia-Yi. · Department of Orthopaedics.
Key points
From the paper's conclusion- Standardized biplanar radiography demonstrated close agreement with CT in assessing femoral anteversion. Although a significant difference was observed between the 2 methods, its magnitude was small and unlikely to be clinically meaningful, supporting the use of standardized plain radiography as an alternative in clinical practice.
Abstract
BACKGROUND: Increased femoral neck anteversion is a common cause of intoeing gait in children. Computed tomography (CT) is the reference standard for measuring femoral anteversion; however, its use is limited by radiation exposure. This study evaluated the agreement between femoral neck anteversion angle (FAA) measurements obtained using standardized plain radiography and CT. METHODS: Data from patients aged 5 to 12 years with an intoeing gait who underwent both femoral CT and standardized anteroposterior and lateral radiography were retrospectively analyzed. FAA measurements were calculated from biplanar radiographs using a geometric method and compared with CT measurements. Agreement between the 2 methods was assessed using a paired test, Pearson correlation coefficients, and Bland-Altman analysis. RESULTS: Eighteen paired limb measurements were included. The mean FAA measured using radiography was 32.8±6.7 degrees, whereas the mean FAA measured using CT was 31.8±7.5 degrees. The mean difference was 1.0±1.7 degrees (P=0.020). Reliability was excellent for both measurement methods. The Bland-Altman analysis revealed a mean bias of 1.0 degrees, with limits of agreement ranging from -2.3 to 4.3 degrees, without evidence of proportional bias. CONCLUSIONS: Standardized biplanar radiography demonstrated close agreement with CT in assessing femoral anteversion. Although a significant difference was observed between the 2 methods, its magnitude was small and unlikely to be clinically meaningful, supporting the use of standardized plain radiography as an alternative in clinical practice. LEVEL OF EVIDENCE: Level IV-case series.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A simple maximum intensity projection method for measuring proximal femoral anteversion: An observer reliability study.Journal of experimental orthopaedics · 2026
- Exploring the Relationship Between Femoral Neck Torsion Angle and Anteversion Angle Through Three-Dimensional Reconstruction in a Fixed Coordinate System.International journal of general medicine · 2026
- EP1.48 Comparison of 2D versus 3D measurements of Lateral Center Edge Angle in Patients with Femoroacetabular Impingement Syndrome and Hip Instability: A study of 754 hipsJournal of Hip Preservation Surgery · 2026
- TP3.3 Lateral Center-Edge Angle Measurements on Computed Tomography Are Higher Compared To Measurements On Plain Radiograph But Alpha Angle and Tönnis Angle Are Similar: A Systematic Review and Meta-AnalysisJournal of Hip Preservation Surgery · 2026
- Standing Long-Leg Radiographs Underestimate Varus Alignment and Joint Line Obliquity Compared With Computed Tomography in Japanese Patients.Cureus · 2026
- Mobile application-based assessment of rotational changes after surgical treatment for pediatric femoral shaft fracture: A retrospective observational study.Medicine · 2026