TP3.3 Lateral Center-Edge Angle Measurements on Computed Tomography Are Higher Compared To Measurements On Plain Radiograph But Alpha Angle and Tönnis Angle Are Similar: A Systematic Review and Meta-Analysis
Dr Iyad Ali, Mr Scott Fong, Mr Raquel Rosa, Mr Anshu Jonnalagadda, Mr Shrey Ramesh, Mr Michael Lee, Dr Jay Moran, Dr Alaina Durden,
Key points
From the paper's conclusion- This purpose of this systematic review was to evaluate studies comparing plain radiography (XR) and computed tomography (CT) measurements of LCEA, AA, and TA in hip preservation patients.
Abstract
Introduction Radiographic evaluation is central to the assessment of femoroacetabular impingement and acetabular dysplasia, with key parameters including the lateral center-edge angle (LCEA) and Tönnis angle (TA) for acetabular coverage and the alpha angle (AA) for cam morphology. This purpose of this systematic review was to evaluate studies comparing plain radiography (XR) and computed tomography (CT) measurements of LCEA, AA, and TA in hip preservation patients. Methods A systematic review was conducted in October 2025 in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines using PubMed, Cochrane Central Register of Controlled Trials (CENTRAL), and Scopus databases. Studies comparing CT and plain radiography measurements of hip preservation parameters were included. Meta-analysis was performed where applicable; heterogeneity was assessed using I2 statistics. P<0.05 was considered statistically significant. Results Twelve studies comprising 1,188 hips (1,008 patients) met inclusion criteria. The cohort was predominantly female (70.7%), with mean ages ranging from 25 to 39 years. XR measurements of LCEA were significantly lower than CT in four of six studies (range: −9.14° to +1.3°). AA differences ranged from −6.49° to +11.4°, with three of five studies reporting significantly higher values on XR and one reporting the inverse. TA differences ranged from −2.60° to +3.92° with inconsistent directionality. Interobserver reliability was excellent (Intraclass coefficient (ICC) > 0.75) for LCEA and TA on both modalities, while AA demonstrated greater variability across studies (ICC 0.09–0.929 for CT, 0.43–0.89 for XR). Meta-analysis demonstrated that LCEA was underestimated on XR relative to CT (SMD 0.34, 95% CI 0.08–0.61, p = 0.01), while AA and TA showed no significant differences. Heterogeneity was substantial (I2=79–83%). Conclusion LCEA measurements were consistently lower on XR than CT. AA differences were inconsistent and largely view-dependent; insufficient TA data precluded any conclusion. Reliability was excellent for LCEA and TA but more variable for AA. Significance/Clinical Relevance These findings suggest that LCEA measurements on XR underestimate acetabular coverage relative to CT, potentially overestimating the degree of acetabular dysplasia.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- EP1.48 Comparison of 2D versus 3D measurements of Lateral Center Edge Angle in Patients with Femoroacetabular Impingement Syndrome and Hip Instability: A study of 754 hipsJournal of Hip Preservation Surgery · 2026
- FP1.7 Is the Lateral Center-Edge Angle Truly Static? A Conceptual Framework for Dynamic Acetabular CoverageJournal of Hip Preservation Surgery · 2026
- EP4.14 Introducing the Impingement Index: Patient and Three-dimensional CT Drivers of Hip Internal Rotations Validated Across a Prospective Multicenter StudyJournal of Hip Preservation Surgery · 2026
- EP1.39 Comparison of methods for assessment of the sagittal orientation of the acetabulumJournal of Hip Preservation Surgery · 2026
- TP5.1 Acetabular Over-Coverage Predicts Revision After Femoroacetabular Impingement Surgery: Association of Static and Dynamic Lateral Center-Edge Angle Classification with Reoperation RiskJournal of Hip Preservation Surgery · 2026
- TP1.2 Increased correction of lateral centre edge angle after periacetabular osteotomy is associated with a reduction in hip flexion and internal rotation: A three-dimensional computed tomography simulation studyJournal of Hip Preservation Surgery · 2026