Journal of orthopaedic trauma

A Novel Technique to Maintain Skeletal Traction During CT Imaging for Acetabular Fractures with Mechanical Instability.

Allen A Champagne, Grant H Cabell, Alexander W Parsons, Emily J Harman, Jacob S Torrey, Christian A Pean, Rachel Reilly, Malcolm R DeBaun

Department of Orthopaedic Surgery, Duke University Medical Center, Durham, NC, USA.

Observational · n=15

Key points

From the paper's conclusion
  • In this technical report, a traction apparatus that includes a ratchet strap connected to a digital scale was applied to maintain skeletal traction during CT imaging of acetabular fractures with mechanical instability.

Abstract

Maintaining skeletal traction in patients with acetabular fracture dislocations and associated mechanical instability remains a challenge during computed tomography (CT) acquisition. Further, multiple transfers and prolonged periods without traction pose an increased risk for recurrent dislocation episodes following closed reduction while awaiting definitive surgery. In this technical report, a traction apparatus that includes a ratchet strap connected to a digital scale was applied to maintain skeletal traction during CT imaging of acetabular fractures with mechanical instability. A cohort of 15 patients (meanage=44.0 +/- 21.5 years old, 10M/5F, Table 1) was retrospectively reviewed following implementation of the described method with no dislocation episodes during serial CT imaging prior to operative fixation. This technique is low-cost, vendor-agnostic, and does not require additional radiation exposure to trainees or radiologic technologists to manually maintain traction.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts