A North American experience with the "French Paradox" technique in total hip arthroplasty: up to 5-year follow-up.
Braden V Saba, Alan Lam, Matthew Barnes, Michael Blankstein, Chad A Krueger, Ran Schwarzkopf
Department of Orthopedic Surgery, NYU Langone Health, New York, NY. · Department of Orthopaedic Surgery, Rothman Orthopaedic Institute, Philadelphia, PA.
Key points
From the paper's conclusion- The French Paradox cement technique demonstrated exceptional outcomes up to 5 years with no instances of femoral complications (loosening, subsidence, periprosthetic fracture, or stem failure). In appropriately selected patients and with compatible femoral stem designs, the French Paradox cement technique represents an effective cemented femoral fixation strategy with excellent early to mid-term survivorship.
Abstract
BACKGROUND: Cement use in total hip arthroplasty (THA) is a topic of ongoing research and debate. The French Paradox cement technique, first described in European arthroplasty literature, achieves a thin (<2 mm) cement mantle by preparing the femoral canal only slightly larger than the femoral implant. The technique was coined the "French Paradox" because a French-designed stem showed excellent long-term outcomes despite previous evidence that thin cement mantles can be prone to failure. PURPOSE: The purpose of this study was to describe a North American experience with femoral stems implanted using the French Paradox cement technique. STUDY DESIGN/METHODS: This was a retrospective study of 125 patients who underwent primary, unilateral THA using the French Paradox cement technique between 2020 and 2023 at 3 academic health systems and had minimum 2-year follow-up. Demographic, implant-related, perioperative, radiographic, and complication variables, as well as patient-reported outcome measures and postoperative variables, were collected at baseline and all available postoperative follow-ups. Chi-square, t test, and ANOVA were used to assess statistical significance, with a significance level of 0.05. LEVEL OF EVIDENCE: IV. RESULTS: Of the 125 patients, 84% were women, 86% were White, and 5% were current smokers. The mean age of the cohort was 73 years, the mean Charlson Comorbidity Index (CCI) was 3.6%, and 96% of patients had an ASA score of either II or III. There was 1 readmission (0.8%) within 90 days of surgery, which was due to sepsis of gastrointestinal origin. Two patients (1.6%) underwent revision at a mean time of 14 months, 1 for acute PJI and 1 for acetabular component loosening. There were no femoral stem complications, including no instances of loosening, periprosthetic fracture, or stem subsidence. Patient-reported outcome measures (PROMs) showed consistent and meaningful improvements in HOOS, JR and Forgotten Joint Score (FJS). CONCLUSION: The French Paradox cement technique demonstrated exceptional outcomes up to 5 years with no instances of femoral complications (loosening, subsidence, periprosthetic fracture, or stem failure). In appropriately selected patients and with compatible femoral stem designs, the French Paradox cement technique represents an effective cemented femoral fixation strategy with excellent early to mid-term survivorship.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Operative Outcomes of Cemented Hip Arthroplasty: An Examination of the French Paradox.The Journal of arthroplasty · 2026
- Association between cemented and uncemented cups and risk of revision in patients aged 65 years or older following primary total hip arthroplasty: a study of 310,515 patients from the Nordic Arthroplasty Register Association.Acta orthopaedica · 2026
- Periprosthetic Femoral Fracture in Hip Arthroplasty Using Cemented Stems: Toward a Construct-Level and Time-Dependent Perspective.Bioengineering (Basel, Switzerland) · 2026
- Cemented total hip arthroplasty reduces early complications: a Japanese nationwide propensity-matched studyArchives of Orthopaedic and Trauma Surgery · 2026
- Periprosthetic strain-adaptive bone remodeling of conservative metaphyseal fitting versus conventional anatomic cementless femoral stem.Hip international : the journal of clinical and experimental research on hip pathology and therapy · 2026
- Quantifying the Age-Dependent Risk of Periprosthetic Femoral Fracture Following Cementless Total Hip Arthroplasty: An Analysis using Age as a Continuous Variable.The Journal of arthroplasty · 2026