P134. Noncontact breathing and acoustic assessment for pediatric sleep-disordered breathing diagnosis
D Nguyen, A Pinczel, C O’Reilly, A Teare, A Leviton, T Nguyen, M O’Grady, D Eckert,
Key points
From the paper's conclusion- Arousal index N2NV was 1.4 [1.2, 1.7] events/hr.
Abstract
Objectives To evaluate the feasibility of a novel unobtrusive under-mattress and bedside sensor system for continuous, multi-night home tracking of sleep, respiratory and snoring disturbances in children. Methods In this ongoing trial, children aged 2–11 years with suspected OSA undergo ~2-weeks of in-home non-contact mattress-sensor and ≥3-nights of pulse oximetry recordings. Device recorded cardiorespiratory and motion signals undergo off-line processing, via an adult-trained multi-task deep learning model, to extract sleep and respiratory metrics. The device also performs real-time extraction of acoustic features in 20 msec intervals to enable off-line automated evaluation of >600 ambient/clinical noise types (e.g., snoring, coughing, gasping). Standard deviation in derived metrics to date was used to evaluate night-to-night variability (N2NV). Data are reported as mean [95% CI]. Results In 11 children studied to date, 98 nights of device data (2–15 nights/participant, 973 hours total, 9.9 hours/night) and 35 nights of oximetry (282 hours; 8.1 hours/night) were successfully recorded. Device capture succeeded in 8/11 children with technical loss in 3 due to battery failure (2 children, 20% nights lost) or microSD capacity full (1 child, 80% nights lost). REM sleep showed lower N2NV than other stages (Wake: 9.1 [5.9, 12.2]%; NREM: 8.8% [5.8, 11.8]%; REM: 2.2 [1.7, 2.8]%). AHI N2NV was 1.1 [0.8, 1.4] events/hr, driven by hypopnea (0.9) and central apnoea (0.4) variation. Arousal index N2NV was 1.4 [1.2, 1.7] events/hr. Conclusions This study demonstrates the technical feasibility of high-fidelity, multi-night, non-contact home sleep monitoring. Further paediatric-specific device algorithm fine-tuning should enhance diagnostic capabilities.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Contactless multimodal vital sign monitoring in paediatric sleep laboratory alongside polysomnography: protocol of a pilot studyFrontiers in Digital Health · 2026
- P064. Sonomat Versus Video/PSG for quantifying nocturnal body movements in childrenSLEEP advances · 2026
- Advancing Sleep Testing for Children: In-Laboratory Validation of a Type 2 Sleep-Monitoring System Designed for Home-Based Pediatric Assessment.Children (Basel, Switzerland) · 2026
- O016. Combined Sonomat and AI-Oximetry for Paediatric Neurodevelopmental Disability OSA ScreeningSLEEP advances · 2026
- O049. Ventilation and Effort Monitoring in OSA via Non-Contact Bed SensingSLEEP advances · 2026
- Contactless Oxygen Desaturation Prediction and Oxygen Desaturation Index (ODI) Estimation from Nocturnal Breathing Sounds via Deep Learning.Sleep · 2026