O049. Ventilation and Effort Monitoring in OSA via Non-Contact Bed Sensing
T Nguyen, A Pinczel, C O'Reilly, K Reynolds, A Vakulin, D Eckert, B Lechat, A Carney,
Key points
From the paper's conclusion- A pretrained 100-million parameter hybrid CNN Transformer was used to covert raw non-contact signals into estimated ventilation and inspiratory effort.
Abstract
Study Objectives To develop a novel non-contact approach to assess ventilation and inspiratory effort for comprehensive multi-night assessment of obstructive sleep apnoea (OSA). Methods Thirteen patients with OSA underwent in-laboratory physiological sleep studies with full polysomnography, calibrated airflow and oesophageal pressure to assess ventilation and inspiratory effort. Simultaneous non-contact mattress-based cardiorespiratory ballistographic signals were also recorded, followed by ≥1-week of in-home mattress-sensor recordings. A pretrained 100-million parameter hybrid CNN Transformer was used to covert raw non-contact signals into estimated ventilation and inspiratory effort. Model performance was evaluated using leave-one-out cross-validation at both epoch and respiratory event levels, before final training for home deployment and evaluation of normalised mean [95% CI] absolute error (nMAE) evaluation. Results nMAE for ventilation was 11.9 [10.4–13.5]%, and for inspiratory effort was 11.8 [10.6–13.1]%. Moderate correlations were observed between estimated and reference signals, with Pearson correlations of 0.50 [0.43–0.58] for ventilation and 0.53 [0.42–0.65] for inspiratory effort. Near-miss accuracy within 5% was 56% for ventilation and 54% for inspiratory effort, increasing to 73% and 74% within 10%. Following the lab study, 12 of 13 participants completed multi-night home evaluations. Ventilation showed higher night-to-night variability (42 [30–54]%) than inspiratory effort (13 [10–17]%). Conclusions This study demonstrates, for the first time, the feasibility of comprehensive multi-night in-lab and in-home assessment of ventilation and inspiratory effort beyond conventional OSA severity metrics. This approach enables multi-night evaluations of ventilation and inspiratory effort and thus mechanistic insights into OSA not possible with PSG alone.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- P134. Noncontact breathing and acoustic assessment for pediatric sleep-disordered breathing diagnosisSLEEP advances · 2026
- Contactless Oxygen Desaturation Prediction and Oxygen Desaturation Index (ODI) Estimation from Nocturnal Breathing Sounds via Deep Learning.Sleep · 2026
- Estimating sleep apnea severity from diaphragmatic electromyography signals.Physiological measurement · 2026
- O040. Event-specific ventilatory response to arousal improves arousal threshold estimationSLEEP advances · 2026
- An explainable spatial–temporal transformer framework with time-stretch encoding for cross-dataset sleep apnea detectionDiscover Applied Sciences · 2026
- A Contactless Approach for Accurate Sleep Stage Detection Using the Sleepal AI LampPhysiological Measurement · 2026