Key points
From the paper's conclusion- Four human scorers who independently classified capsule ingestion and excretion events in pre-existing time-series temperature data (3 capsules from each of 10 participants, 30 capsules total).
Abstract
Introduction Ingestible capsule thermometers are the most practical method to track core body temperature (CBT) changes in free-living human experiments. However, with no system to guide capsule ingestion: multi-day recordings require either simple once-daily capsule swallowing, or complex temperature self-monitoring. Automated ingestion guidance could help to reduce participant burden and data loss. This study seeks to develop and test an algorithm to reliably detect capsule excretion. Methods A simple logic-based algorithm was developed to classify capsule excretion events using normal physiological range and rate-of-change of CBT. The algorithm design also sought to identify artefactual temperatures, both environmental pre-ingestion, and consumption-based post-ingestion. Four human scorers who independently classified capsule ingestion and excretion events in pre-existing time-series temperature data (3 capsules from each of 10 participants, 30 capsules total). The scorers subsequently conferred to produce consensus capsule excretion scoring. Agreement was assessed, both between human scorers, and between consensus and algorithm, via intra-class correlation coefficients (ICC). Results Human consensus identified 19 expulsion events, 10.1% of which were missed during independent labelling, ICC=1.00, with all 4 scorers always within 2 samples (60 s). The algorithm identified 18 of 19 excretion events, or 5.3% missed, ICC=1.00, within 2 samples of human consensus in 17 cases. Conclusions This work builds towards automated capsule ingestion guidance via a loss-detection algorithm. In most cases, the algorithm and human scorers closely agreed, with the algorithm providing greater reliability than the average human. An upcoming trial will assess real-world performance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A miniaturized ingestible temperature sensor for continuous internal monitoringNature Electronics · 2026
- Battery-free ingestible electronic capsule with programmable high-output soft actuation for active gastrointestinal interventions.Science advances · 2026
- Inter- and Intra-Observer Reliability for Colon Capsule CLEansing Assessment and Report.Endoscopy international open · 2026
- Evaluation of an audio-based monitoring system for detecting retching and vomiting in gastroparesis: an observational cohort studynpj gut and liver. · 2026
- A Comprehensive Review of Non-Invasive Core Body Temperature Measurement TechniquesSensors · 2026
- Intracellular Luminescence Thermometry: A Story of Disagreement, Trust, and HopeACS Physical Chemistry Au · 2026