O041. Impact of polysomnography scoring method on PUP-derived OSA endotypic traits
S Joosten, S Landry, H Vu, A Turton, G Hamilton, M Howard, Y Khor, S Sands,
Key points
From the paper's conclusion- CONCLUSION PUP-derived endotypic traits show greater robustness to scoring variability than conventional sleep study parameters.
Abstract
Background Phenotyping using polysomnography (PUP) calculates obstructive sleep apnoea (OSA) endotypic traits from staged and scored polysomnography data. Whether scoring variability between human scorers and autoscoring algorithms meaningfully affects PUP-derived endotype measurements remains unknown. Methods 133 participants (91M, 42F; age 68.8 years; AHI 27.1/hr) underwent polysomnography (in-lab=103, home=30). Studies were independently scored by sleep scientists at Austin (A) and Monash (M), and by Compumedics autoscoring algorithm (C). Sleep study parameters and PUP-derived endotypic traits — VpassiveT, Vmin, Vactive, and loop gain (LG1, LGn) — were compared using linear mixed models, ICC(2,1) and Bland-Altman analysis. Known physiological changes with body position (supine vs non-supine) and sleep stage (NREM vs REM) served as biological benchmarks to assess whether all three methods equivalently detected expected endotypic trait variation. RESULTS Austin and Monash demonstrated excellent agreement, with ICCs exceeding 0.90 for all variables except supine AHI. Compumedics showed variable agreement, with moderate ICCs for REM AHI, NREM sleep percentage, supine AHI, and Fhypopnoeas. The discrepancy in agreement between method comparisons was significantly attenuated for PUP endotype traits relative to conventional sleep study parameters (mean Fisher z-difference 0.42 vs 0.75; LoA width ratio 1.26 vs 1.93; both p<0.05). All three scoring methods demonstrated equivalent sensitivity to positional and sleep-stage physiological changes across all endotypic traits. CONCLUSION PUP-derived endotypic traits show greater robustness to scoring variability than conventional sleep study parameters. All three scoring approaches demonstrated equivalent capacity to detect known physiological changes, supporting the validity and reliability of PUP endotyping across different scoring methods.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- P164. Proxy Endotyping in Ambulatory OSA: A Community Prevalence StudySLEEP advances · 2026
- Differences in Endotypic Traits Between Obstructive Sleep Apnoea Patients With and Without Excessive Daytime SleepinessRespirology · 2026
- Association of Endotypic Traits and Their Interaction With Severity of Obstructive Sleep ApneaRespirology · 2026
- P163. Are Patient-Reported Outcomes Sensitive Across OSA Phenotype Blends?SLEEP advances · 2026
- Endotypic Traits of Hypopnea-Predominant OSA: The Role of Hypopnea Criteria.Journal of sleep research · 2026
- Predicting optimal CPAP pressure in obstructive sleep apnea among Chinese patients using respiratory endotype derived from polysomnography.Scientific reports · 2026