Predicting optimal CPAP pressure in obstructive sleep apnea among Chinese patients using respiratory endotype derived from polysomnography.
Jichu Zhu, Xia Hu, Xiaoyue Wang, Wenjie Liu, Junjie Song, Ji Chen, Jingchun Luo, Chen Chen,
Department of Neurology, Huashan Hospital, Fudan University, Shanghai, China. · Human Phenome Institute, Fudan University, Shanghai, China.
Key points
From the paper's conclusion- The prediction model included loop gain (LG1), ventilation capacity (Vpassive, Vmin), BMI, apnea index (AI), mean respiratory event-related oxygen desaturation (RE-OD-Mean), longest apnea duration (Ap-Dur-Long), and respiratory-related arousal index (RR-ArI): CPAP = 0.708 + 1.804×LG1 + 0.023×Vpassive - 0.015×Vmin + 0.117×BMI + 0.003×AI - 0.074×RE-OD-Mean + 0.019×Ap-Dur-Long + 0.043×RR-ArI.
Abstract
Accurately predicting optimal continuous positive airway pressure (CPAP) using traditional PSG parameters remains challenging. Respiratory endotypes derived from PSG can reflect the pathophysiological mechanisms of diseases to a certain extent and are expected to provide a novel perspective for individualized pressure prediction. 114 Chinese adults with obstructive sleep apnea (OSA) underwent two overnight in-laboratory PSG recordings. Optimal CPAP pressure was defined by standardized manual titration performed on the second night. The analysis incorporated three sets of variables: respiratory endotypes, anthropometric indicators, and PSG respiratory parameters. After initial correlation screening, significant variables were entered into a stepwise multiple linear regression model. The dataset was randomly split into training (80%) and validation (20%) sets to assess predictive performance. A total of 114 participants (15 mild, 38 moderate, 61 severe OSA) were included. The prediction model included loop gain (LG1), ventilation capacity (Vpassive, Vmin), BMI, apnea index (AI), mean respiratory event-related oxygen desaturation (RE-OD-Mean), longest apnea duration (Ap-Dur-Long), and respiratory-related arousal index (RR-ArI): CPAP = 0.708 + 1.804×LG1 + 0.023×Vpassive - 0.015×Vmin + 0.117×BMI + 0.003×AI - 0.074×RE-OD-Mean + 0.019×Ap-Dur-Long + 0.043×RR-ArI. The final model demonstrated acceptable predictive performance in the internal validation set (R² = 0.497; RMSE = 1.507 cmH₂O). Among the retained predictors, LG1 showed the largest effect size, with each 1-unit increase associated with an approximately 1.8 cmH₂O higher predicted CPAP pressure. Integrating respiratory endotypes with anthropometric indicators and PSG respiratory parameters provides a mechanism-based framework for CPAP pressure prediction. Collapsibility traits (Vpassive, Vmin) and ventilatory control stability (LG1) substantially enhance predictive accuracy, offering a more individualized approach to PAP therapy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Machine learning prediction of the change in sleepiness following continuous positive airway pressure in obstructive sleep apnea: a multi-cohort analysis.Sleep · 2026
- Scalable Sleep Apnoea Endotype Profiling and Estimated Oral Appliance Treatment Response in a Large Clinical Cohort.Respirology (Carlton, Vic.) · 2026
- Association of Endotypic Traits and Their Interaction With Severity of Obstructive Sleep ApneaRespirology · 2026
- P164. Proxy Endotyping in Ambulatory OSA: A Community Prevalence StudySLEEP advances · 2026
- Differences in Endotypic Traits Between Obstructive Sleep Apnoea Patients With and Without Excessive Daytime SleepinessRespirology · 2026
- O041. Impact of polysomnography scoring method on PUP-derived OSA endotypic traitsSLEEP advances · 2026