Multimodal Respiratory Event Detection Leveraging Signal Complementarity under Intermittent SpO₂ Loss.
Authors Linh Thanh Duy Tran, Hoang Trang Nguyen, Do Quoc Vu, Bui Thi Hong Loan, Vinh Nhu Nguyen, Tran Ngoc Dang
Center for Family Doctors, University of Medicine and Pharmacy at Ho Chi Minh City, 70000, Vietnam. · Faculty of Applied Sciences, University of Liège, 4000, Belgium.
Key points
From the paper's conclusion- Within probability-level late fusion, performance depended more on signal complementarity than modality count. Quality-aware probability integration enabled robust classification under realistic SpO₂ dropout without retraining, but fixed-epoch late fusion limited exploitation of temporally misaligned oximetry information.
Abstract
STUDY OBJECTIVES: Current multimodal approaches for automated sleep apnea detection usually assume continuous signal availability, although sensor dropout is common in clinical practice. We evaluated probability-level late fusion across signal configurations and missing-data conditions to determine whether performance depends more on signal complementarity or modality count. METHODS: We trained random forest base classifiers on EEG, ECG, SpO₂, and abdominal effort features from 148 patients. Each classifier generated three-class posterior probabilities, which were concatenated and input to a meta-classifier for final epoch-level prediction. Unreliable SpO₂ epochs were excluded only from SpO₂ base-model fitting but retained during meta-classifier training and testing using uniform placeholder probabilities [0.333, 0.333, 0.333] plus the isBad quality flag. Selected unimodal and multimodal configurations were evaluated in 37 held-out patients using macro-F1 as the primary metric. Bootstrap confidence intervals stratified by SpO₂ quality assessed robustness under dropout. RESULTS: Abdominal effort alone achieved macro-F1 = 0.996. SpO₂ + abdominal effort achieved the highest macro-F1 = 0.997, only marginally above abdominal effort alone. ECG + EEG outperformed SpO₂ + ECG and SpO₂ + EEG despite lacking direct respiratory or oxygenation information. SpO₂ + EEG showed degraded performance (macro-F1 = 0.739; hypopnea precision = 0.203). Adding SpO₂ to ECG + EEG reduced performance (0.872 vs 0.899). Performance remained stable despite 30.7% SpO₂ dropout. CONCLUSIONS: Within probability-level late fusion, performance depended more on signal complementarity than modality count. Quality-aware probability integration enabled robust classification under realistic SpO₂ dropout without retraining, but fixed-epoch late fusion limited exploitation of temporally misaligned oximetry information.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Spectral Features Dominate BCG Respiratory-Event Detection: A Large-Scale Patient-Independent Comparison of Feature Groups in Sleep Apnea PatientsarXiv · 2026
- A dual-branch metric-learning framework for obstructive sleep apnea detectionScientific Reports · 2026
- Dense temporal sleep apnea profiling from single-channel PPG with downstream AHI estimation: a large-scale retrospective feasibility study.Physiological measurement · 2026
- A novel algorithm integrating multimodal information for improving OSA-related sleep staging.Artificial intelligence in medicine · 2026
- Multi-Window Temporal Context for ECG-Based Sleep Apnea Detection Under Limited Apnea-Label Availability.Diagnostics (Basel, Switzerland) · 2026
- O041. Impact of polysomnography scoring method on PUP-derived OSA endotypic traitsSLEEP advances · 2026