Comparison of 99mTc-Phytate and 99mTc-Antimony Trisulfide in sentinel lymph node detection: a lymphoscintigraphy study in breast cancer patients.
Saba Madani, Esmaeil Gharepapagh, Mehdi Salehi Barough, Noushin Benai Rezaieh, Majid Montazer, Morteza Azizi, Sahar Rezaei
Department of Medical Radiation Engineering, CT.C., Islamic Azad University, Tehran, Iran. · Department of Nuclear Medicine, Medical School, Tabriz University of Medical Sciences, Tabriz, Iran.
Key points
From the paper's conclusion- 99mTc-Phytate achieved 100% detection (28 of 28 patients), while 99mTc-Antimony Trisulfide achieved 90.9% (10 of 11 patients).
Abstract
Sentinel lymph node biopsy is critical for breast cancer staging and management. While 99mTc-Phytate is the established standard radiotracer, 99mTc-Antimony Trisulfide has limited clinical application due to radiopharmaceutical supply constraints. This proof-of-concept study evaluates both radiotracers' diagnostic effectiveness and validates 99mTc-Antimony Trisulfide as a viable alternative. This institutional study included 39 breast cancer patients undergoing sentinel lymph node biopsy. Patients received either 99mTc-Phytate (n = 28; 71.8%) or 99mTc-Antimony Trisulfide (n = 10; 25.6%) via periareolar (n = 24) or peritumoral (n = 15) injection. Sentinel lymph node identification and gamma probe concordance were analyzed. Mean patient age was 53.5 ± 9.5 years. Invasive ductal carcinoma predominated (87%). 99mTc-Phytate achieved 100% detection (28 of 28 patients), while 99mTc-Antimony Trisulfide achieved 90.9% (10 of 11 patients). Intraoperative gamma probe concordance was 100% in all successfully visualized cases (38 of 38). Both radiotracers effectively identify sentinel lymph nodes with high diagnostic accuracy. While 99mTc-Phytate remains the preferred first-line agent, 99mTc-Antimony Trisulfide represents a validated alternative, particularly valuable in resource-limited settings or during radiopharmaceutical supply disruptions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Technetium-99m stannous phytate versus technetium-99m sulfur colloid for sentinel lymph node mapping in breast cancer: A single-center retrospective study.Medicine · 2026
- [99mTc]Tc-Tilmanocept sentinel node biopsy and long-term outcomes in melanoma: A cohort study and literature review.European journal of surgical oncology : the journal of the European Society of Surgical Oncology and the British Association of Surgical Oncology · 2026
- A Multicenter Non‐Inferiority Randomized Controlled Trial of Sentinel Lymph Node Biopsy in Early Breast Cancer: Conventional Dual Tracer Versus Superparamagnetic Iron OxideWorld Journal of Surgery · 2026
- Clinical impact of second radiotracer injection after failed lymphoscintigraphy in breast cancer sentinel lymph node biopsy: a retrospective cohort study.World journal of surgical oncology · 2026
- Outcomes of methylene blue single-dye sentinel lymph node biopsy in early breast cancer: a retrospective cohort study from a resource-limited tertiary centreWorld Journal of Surgical Oncology · 2026
- Sentinel lymph node biopsy using methylene blue-fluorescein dye combination in post neo-adjuvant chemotherapy node negative (ycN0) breast cancer patients: A validation study.Tropical doctor · 2026