Reproducibility of 3.0 T single-frequency cardiac MR elastography for quantification of left ventricular myocardial stiffness.
Jun Wang, Yong Cheng, Yewen Jiang, Zijun Zheng, Zhanglei Li, Zhen Wang, Shutian An, Jun Chen,
Department of Radiology, The First Affiliated Hospital of Anhui Medical University, Research Center of Clinical Medical Imaging, Anhui Province Clinical Image Quality Control Center, Hefei, Anhui 230022, China. · Department of Radiology, Mayo Clinic, Rochester, MN 55905, United States.
Key points
From the paper's conclusion- 3D single-frequency 140-Hz cardiac MRE at 3.0 T provides excellent short- and long-interval reproducibility for LV myocardial stiffness quantification. The SDC95 values may help distinguish true longitudinal stiffness changes from measurement variability.
Abstract
BACKGROUND: Cardiac magnetic resonance elastography (MRE) allows the non-invasive quantification of myocardial stiffness, but long-interval reproducibility data at 3.0 T single-frequency 140-Hz remain limited. PURPOSE: To evaluate the short- and long-interval reproducibility of 3.0 T cardiac MRE for left ventricular (LV) myocardial stiffness across healthy volunteers and patients with conditions associated with elevated myocardial stiffness. MATERIALS AND METHODS: This prospective single-center study included 69 participants: 60 healthy volunteers and 9 with cardiovascular disease (6 with aortic stenosis and 3 with long-standing hypertension). All participants underwent baseline cardiac MRE (scanner: Signa Premier 3.0 T, GE Healthcare, driver: Resoundant), an immediate short-interval rescan (SIR) within 5 minutes, and a long-interval rescan (LIR) after approximately 1 month. Left ventricular myocardial stiffness and octahedral shear strain signal-to-noise ratio were measured independently by 2 readers. Reproducibility was assessed using Bland-Altman analysis, intraclass correlation coefficients (ICCs), within-subject coefficient of variation, standard error of measurement, and smallest detectable change at the 95% confidence (SDC95) level. RESULTS: Baseline LV myocardial stiffness was higher in the disease group than in healthy volunteers, 11.73 ± 1.01 kPa and 7.80 ± 0.70 kPa (mean ± SD; P < .001), respectively. Inter-reader agreement was excellent across all timepoints, with ICCs of 0.970 at baseline (95% CI, 0.953-0.982), 0.966 for SIR (95% CI, 0.945-0.979), and 0.962 for LIR (95% CI, 0.939-0.976). Within-reader scan-rescan reproducibility was also excellent. For Reader 1, stiffness ICC was 0.979 for the SIR (95% CI, 0.966-0.987) and 0.957 for the LIR (95% CI, 0.932-0.973), with SDC95 values of 0.616 kPa (95% CI, 0.528-0.741) and 0.869 kPa (95% CI, 0.744-1.044), respectively. Reader 2 showed excellent reproducibility, with ICCs ≤0.943. CONCLUSIONS: 3D single-frequency 140-Hz cardiac MRE at 3.0 T provides excellent short- and long-interval reproducibility for LV myocardial stiffness quantification. The SDC95 values may help distinguish true longitudinal stiffness changes from measurement variability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluating the impact of passive driver position on image consistency and repeatability in 3.0T cardiac magnetic resonance elastography.Frontiers in radiology · 2026
- Effect of Driver Material Properties and Excitation Frequencies on Quantitative Myocardial Stiffness Measurements in Magnetic Resonance ElastographyiRADIOLOGY · 2026
- Comparative Precision of 3D MRE and 2D MRE for Measurement of Liver Stiffness in Adults with Severe ObesityRadiology · 2026
- Methodological considerations in estimating active muscle stiffness index.Journal of biomechanics · 2026
- 3D ultrasound shear wave elastography quantifies myocardial stiffness and anisotropy in the human heart.Physics in medicine and biology · 2026
- Quantitative assessment of regional myocardial stiffness and anisotropy using 3D Shear Wave ElastographyEuropean Heart Journal · 2026