Neuro-Oncology

EP07.33 Integrating Confocal Laser Endomicroscopy and Label-Free Nanoplasmonic Biosensing for Intraoperative Glioblastoma Tissue Discrimination

L Bauluz, V García-Milán, A Franco, S Marcos, R Martín-Láez, M Ortiz, F Moreno, J Fernandez Luna,

Observational · n=13

Key points

From the paper's conclusion
  • Together with CLE, these findings support the potential complementary role of nanoplasmonic biosensing for intraoperative tissue characterization.

Abstract

Background Maximal safe resection remains a key prognostic factor in glioblastoma. However, the infiltrative nature of glioblastoma often results in poorly defined tumor margins, making intraoperative discrimination between tumor and normal brain tissue challenging. Several intraoperative techniques, including fluorescence-guided surgery and confocal laser endomicroscopy (CLE), have been developed to improve margin identification but rely on subjective interpretation. Besides, they rely on exogenous fluorophores. In this context, a label-free nanoplasmonic biosensor based on extraordinary optical transmission (EOT) enables tissue discrimination through refractive index (RI) measurements. This study evaluates the ability of a nanoplasmonic biosensor to differentiate glioblastoma from peritumoral brain tissue and explores its potential integration with CLE. Material and Methods In this prospective study, ex vivo tissue samples were obtained from patients with histologically confirmed WHO grade IV glioblastoma. Paired samples from the tumor edge and peritumoral brain tissue were collected, and their nature was confirmed by histopathology examination. RI values were recorded using an EOT-based nanoplasmonic biosensor. In a subgroup of cases, the same ex vivo tissue samples were evaluated using the CLE. A diagnostic threshold for the biosensor was determined based on the distribution of RI values. Diagnostic performance was assessed against histopathological diagnosis. Patient recruitment is ongoing to further validate these findings. Results A total of 44 paired tissue samples were analyzed. RI values obtained with the nanoplasmonic biosensor were consistently higher in tumor samples (1.350, IQR 1.344-1.362) compared with peritumoral brain tissue (1.345, IQR 1.339-1.352). Statistical analysis using the Wilcoxon signed-rank test demonstrated a significant difference between the two tissue types (p = 0.004). Receiver operating characteristic (ROC) analysis showed that the biosensor was able to discriminate tumor from peritumoral tissue with an area under the curve of 0.71. Using a diagnostic threshold (RI = 1.342), the biosensor achieved a sensitivity of 88.2% and an overall diagnostic accuracy of 68.2%. In the subgroup of patients in whom intraoperative CLE was performed, the technique discriminated tumor from peritumoral tissue in 11 of 13 cases, corresponding to an overall diagnostic accuracy of 84.6%. Conclusion The EOT-based nanoplasmonic biosensor demonstrated the ability to discriminate glioblastoma from peritumoral brain tissue. Together with CLE, these findings support the potential complementary role of nanoplasmonic biosensing for intraoperative tissue characterization. Its objective readout, low cost, and minimal infrastructure requirements may offer practical advantages for integration into the neurosurgical workflow.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers