Neuro-Oncology

PATH-10 SIGNAL: A Scalable, Real-World Model for Rapid Intraoperative Molecular Classification of Gliomas Using Stimulated Raman Histology

Nicolas Goff, John Markert, David Reinecke, Alexandra Springer, Anna Chen, Minjun Park, Gabrielle Malte, Katie Scotford-Broemmer,

Observational · n=555

Key points

From the paper's conclusion
  • In conclusion, SIGNAL is a lightweight model for intraoperative molecular SRH-based classification of gliomas that exceeds the performance of the best existing models and has been rigorously evaluated in a multi-institutional, pseudo-prospective trial.

Abstract

Previous machine learning models to intraoperatively predict the molecular status of gliomas using stimulated Raman histology (SRH), such as DeepGlioma, have achieved high performance (91.5% accuracy) on curated datasets. However, when used intraoperatively, DeepGlioma (162M parameters) runs slowly on current SRH hardware and underperforms due to its lack of an image rejection mechanism and its validation on curated images. Here, we introduce SRH-Informed Glioma classificatioN with Attention Learning (SIGNAL) (27M parameters), a lighter model with a built-in attention-based rejection mechanism that outperforms DeepGlioma on uncurated clinical datasets. SIGNAL was developed using 1.56 million SRH fields-of-view from 967 adult diffuse glioma patients (December 2017-July 2025; 412 NYU for training and validation, multi-institutional test cohort of 555 patients). SIGNAL uses a ResNet50 backbone pretrained using a hierarchical contrastive loss function followed by a multi-head multi-layer perceptron (MLP). Using a patch-based attention threshold of 0.6, a final MLP was trained to predict glioma subtypes: glioblastoma, oligodendroglioma, or astrocytoma. SIGNAL outperformed DeepGlioma, achieving greater overall accuracy (90.10% vs. 72.59%) while running faster (16.0 vs. 6.7 patches/s). SIGNAL also outperformed DeepGlioma on all three molecular classification tasks, including IDH mutation (accuracy: 93.51% vs. 79.22%), 1p19q codeletion (93.51% vs. 88.31%), and ATRX loss (89.61% vs. 83.98%). SIGNAL’s attention mechanism had a strong positive linear correlation with mean patch cellularity (r = 0.96, p < 0.001) and a strong negative correlation with patch blood coverage (r=-0.99,p<0.001). Finally, subtype and molecular accuracy between tumor core and margin samples were equivalent despite significantly lower patch retention in tumor margins (44.5% vs 60.2%, p < 0.0001). In conclusion, SIGNAL is a lightweight model for intraoperative molecular SRH-based classification of gliomas that exceeds the performance of the best existing models and has been rigorously evaluated in a multi-institutional, pseudo-prospective trial. Its attention-based image quality filter and highly interpretable outputs are key for reliable use intraoperatively.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers