RADT-49 Dosimetric Comparison of adjuvant Stereotactic Radiotherapy (SRT) Versus Conventionally Fractionated Volumetric Modulated Arc Therapy (VMAT) in Glioblastoma Multiforme
Anjali V Ramdulari, Aviral Rastogi, Haresh Kunhi Parambath, Abhijith S, Hardik Panday, Suman Bhasker, Subhash Gupta
Key points
From the paper's conclusion- Aim To perform a dosimetric comparison between hypo fractionated Stereotactic Radiotherapy (SRT) and Conventionally Fractionated Volumetric Modulated Arc Therapy (VMAT) in target coverage, dose conformity, dose homogeneity, and dose bath to normal brain tissue.
Abstract
Aim To perform a dosimetric comparison between hypo fractionated Stereotactic Radiotherapy (SRT) and Conventionally Fractionated Volumetric Modulated Arc Therapy (VMAT) in target coverage, dose conformity, dose homogeneity, and dose bath to normal brain tissue. Methods Dosimetric data from seven patients diagnosed with GBM who were prospectively treated with SRT were included in this study. For each patient, SRT plans delivering 42 Gy in 6 fractions and VMAT plans delivering 60 Gy in 30 fractions were generated. Dosimetric evaluation was performed for both treatment techniques. Planning Target Volume (PTV) parameters analyzed included V80, V95, V100, V105, V110, Homogeneity Index (HI), and Conformity Index (CI). Dose–volume parameters for normal brain tissue excluding the PTV (Brain–PTV) included V5Gy, V10Gy, V25Gy, V28.8Gy, and V30Gy. A paired statistical analysis was conducted to compare dosimetric parameters between the two planning approaches, with a p-value of < 0.05 considered statistically significant. Results SRT plans demonstrated significantly higher values of PTV V95, V105, V110, and Homogeneity Index (HI) compared with conventionally fractionated VMAT plans (p = 0.0434, 0.0097, 0.0163, and 0.0009, respectively), indicating increased dose heterogeneity and greater hotspot formation within the target volume in SRT plans. No statistically significant differences were observed between the two techniques with respect to PTV V80, V100, and Conformity Index (CI), suggesting comparable target coverage and conformity. Evaluation of normal brain tissue excluding the PTV (Brain–PTV) showed statistically significant differences in dose–volume, including V5Gy, V10Gy, V25Gy, V28.8Gy, and V30Gy with p value < 0.001 for all parameters, demonstrating a distinct dose distribution pattern between SRT and conventionally fractionated VMAT techniques. Conclusion SRT demonstrated greater dose heterogeneity and increased high-dose regions within the target volume compared with VMAT plans. Significant differences in dose bath to normal brain were also observed between the two treatment techniques. SBRT provides effective dose intensification with better dosimetric characteristics in normal brain parenchyma that may be advantageous in selected clinical scenarios
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Long-term dosimetric superiority of VMAT over 3D-CRT in pediatric focal brain irradiation: a comprehensive 15-year institutional analysisPathology & Oncology Research · 2026
- Dual optimization in single-isocenter radiosurgery for multiple brain metastases: a dosimetric planning study.Frontiers in oncology · 2026
- Coplanar VMAT versus HyperArc: a comparative study in brain metastases stereotactic radiosurgery.La Radiologia medica · 2026
- Gastric dose-volume parameters and toxicity in left-sided breast radiotherapy: A single-center retrospective comparison of helical tomotherapy and 3-dimensional field-in-field techniquesMedicine · 2026
- Comparative Analysis of Radiation Dose Reduction in Radiosurgery Versus Whole BrainRadiotherapy for Intracranial MetastasesMedical Forum Monthly · 2026
- Evaluation of 3D-CRT vs. VMAT for radiotherapy of whole breast with simultaneous integrated boostActa Oncologica · 2026